Replay Notiffier Module XP6-R 6-Way

Manufacture: Notifire
Product code: XP6-R

The XP6-R 6-way relay output module is a relay module circuit ,Provide relay module design, how to connect a 6-pin relay ,12 months warranty, nationwide delivery ,Contact us for a quote on injectors Vikings spinker

Zalo

Consulting hotline: 0944934114
Product information

General description Replay Notiffier Module XP6-R 6-Way

- The Notifer six-relay control module XP6-R provides an intelligent alarm system with six Form-C relays.

- The first module is addressed 01 to 154 while the remaining modules are automatically assigned to the next higher address fve.

- Provisions are included to disable a maximum of three unused modules.

- A unique set of dry contacts is provided for each module address, which is capable of being wired for a normally open or normally closed operation.

- The module allows the control panel to pass these contacts on command. Unattended is provided for circuit control.

- Each XP6-R module has a blue LED control panel. The control board may cause LEDs to blink, latch or latch o.

- To ensure proper operation this module must be connected to a compatible Notifer fire panel. Features XP6-R 6-way relay output module • Six addressable Form-C forwarding contacts.

• Plug-in 0.75 mm2 to 1.5 mm2 detachable terminal block.

• Status indicators for each point.

• Up to three unused addresses can be disabled,

• Rotary address switch.

• FlashScan® or CLIP operation.

• Includes mounting hardware. Specifications XP6-R 6-way relay output module

- Standby current: 1.45 mA (SLC current drawing with all addresses used; if some addresses are disabled, standby current decreases).

- Alarm current: 32 mA (assuming all six relays have been turned on once and all six solid LEDs ON).

- Temperature range: 0°C to 49°C.

- Humidity: 10% to 85% not air-conditioned.

- Dimensions: 172.72 mm high x 147.32 mm wide x 25.40 mm deep.

- Measuring tape: 0.75 mm2) to 1.5 mm2.

- Maximum SLC wire resistance: 40 or 50 ohms, depends on the panel.

- Maximum IDC wire resistance: 40 ohms.

- Relay current: 30 mA/relay pulse (15.6 ms pulse duration), under panel pulse.

- Relay contact rating: 30 VDC; 70.7 VA

- Current ranking: +3.0 A @ 30 VDC max, resistor, no encoder.

+ Up to 2.0 A @ 30 VDC, resistor, encoder.

+ Up to 1.0 A @ 30 VDC, inductive (L/R = 2 ms), encoder

+ Up to 0.5 A @ 30 VDC, inductive (L/R = 5 ms), encoder

+ 0.9 A @ 110 VDC max, resistor, no encoder. 0.9 A @ 125 VAC max, resistive, no encoder.

+ 0.7 A max @ 70.7 VAC, inductive (PF = 0.35), no encoding. + 0.5 A max @ 125 VAC, inductive (PF = 0.35), no encoder.. IFrame

You can refer to products genuine fire alarm equipment...HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Replay Notiffier Module XP6-R 6-Way

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.13996 sec| 4324.836 kb