- Open Area Visual Smoke Detection (OSID) is an innovative system for reliable, cost-effective smoke detection for large, open spaces requiring standard sensitivity detection.

- In its simplest configuration, OSID uses an imaging device, a camera-like device with a wide field of view, and a wired or battery-powered transmitter that is roughly aligned on the opposite wall in the area. protected area. The transmitter sends both infrared and ultraviolet encoded light signals to the image. If light reception is altered due to the presence of genuine smoke particles, the imaging device will alarm.

Thiết Bị Phát Hiện Khói Bằng hình ảnh Notifier OSI-10 & OSI-90

Notifier Visual Smoke Detector Standard OSI-10 & OSI-90

• UL

• ULC

• FM

• AFNOR

• CE - EMC and CPD

• VdS

• ActivFire

• BOSEC

Specifications of Notifier Visual Smoke Detectors OSI-10 & OSI-90

- Provides 20 to 30 VDC voltage (nominal 24 VDC)

- Current Consumption (at 24 VDC): 8mA (1 emitter) 10mA (7 emitter) Peak (at 24 VDC) in training mode: 31mA

- Current consumption Wired version (at 24 VDC): 350 power Std Power, 800 high power Battery version (1.9 - 3.2 VDC): Built-in battery OSE-RBA: -SP Version:

- 5 years battery life -HP version: 3 years battery life Field wire Measuring cable 0.2

- 4mm² (26-12 AWG)

- Alarm threshold level:

Low - Highest sensitivity / earliest alarm: 20% (0.97 dB)

Average - Average sensitivity: 35% (1.87 dB)

High - Lowest sensitivity/maximum Immune to nuisance smoke conditions: 50% (3.01 dB) Adjustment angle ± 60° (horizontal) ± 15° (vertical)

- Maximum deviation angle ± 2° Dimensions (WHD) Player / Imager: 208 mm x 136 mm x 96 mm (8.19 in. X 5.35 in. X 3.78 in.)

Operating Conditions Notifier Visual Smoke Detectors OSI-10 & OSI-90

Temperature: -10°C to 55°C (14°F to 131°F)

Humidity: 10 to 95% RH (non-condensing). IP Rating IP 44 for Electronics IP 66 for Optical Enclosure Status LEDs Fire Alarm (Red) Trouble / Strength (Bi-color Yellow / Green)

Event Log 10,000 events

 

 

You can refer to products genuine fire alarm equipment...HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Notifier OSI-10 and OSI-90 Visual Smoke Detectors

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.15037 sec| 4329.258 kb