Notifier HS-NCM high-speed network control module

Manufacture: Notifire
Product code: HS-NCM

Top 5 reviews - 1000 comments notifier fire alarm module, notifier fire alarm catalog Provide fire alarm control module types of fire alarm modules, notifier address monitoring modules, Provide documentation for using notifier fire alarm cabinets , 12 month warranty on hochiki fire alarm equipment quotes 2019 , Contact 0917 911 114 specializing in consulting, surveying, designing and constructing fire alarm systems...

Zalo

Consulting hotline: 0944934114
Product information

General description Notifier HS-NCM high-speed network control module

High Speed Network Communication Module (HS-NCM) provides AFP-2800, and AFP-3030 Fire Alarm Control Panel, Network Control Tool NCA-2 and DVC Digital, voice commands by means to connect with high speed Notifier NET™. Six types of HS-NCM are available: HS-NCM-W for connecting nodes using twisted pair wire, HS-NCM-MF for connecting nodes with multimode fiber, HS-NCM-SF for connecting nodes with single-mode audio cable, HS-NCM-WMF for wiring and multimode optical media on the same network, HS-NCM-WSF for wiring and single-mode optical media on the same network and HS-NCM-MFSF to connect multi-mode and single-mode optical media on the same network work.

Each HS-NCM can contain up to two node addresses. For example, an HS-NCM can provide network communication for both the AFP-3030 and the NCA-2. When not connected to a freeboard alarm, the HS-NCM defaults to repeat mode and can be used to increase signal distance or to transmit data between two segmented well-defined networks when wire and fonymous coexist on a network.

Characteristics Notifier HS-NCM high-speed network control module

• Optical media support.

• Open or closed network activity.

• The data is immune to all environmental noises.

• Optical isolation prevents ground loops.

• High speed NOTI

• FIRE

• NET™ Optical Environment.

• Fiber type: 62.5 / 125 micrometers (multi-mode); 50/125 micrometers (multi-mode) or 9/125 micrometers (single mode).

• Maximum attenuation is 10 dB with 62.5/125 cable, and 6.5 dB with 50/125 cable, and 30 dB with 9/125 cable.

• Wavelength (1): 1310 nanometers.

• Connection: LC type.

• Transfer rate 100 Mb baud.

• Data is regenerated at each node.

• Two network ports allow simultaneous connection to the free alarm control panel and for computer programming.

• Allows uploading/downloading software and databases over high speed NOTI

• FIRE • NET™.

• Network support up to 200 nodes

• Fiber, multimode and single fiber options including hybrid cards

• Transfer speed up to 100mb

• 1 x HS-NCM can support 2 buttons

• Can be used as a repeater

Thông số kỹ thuật chung

Temperature and Humidity Range: This system operates at 0°C to 49°C; and at a relative humidity (non-conditioned) 93% ± 2% at 32°C ± 2°C. However, the useful life of the battery standby system and electronic components may be affected. by extreme temperature and humidity ranges. Therefore, this system and all peripherals should be installed in an environment with a nominal room temperature of 15°C to 27°C. Weight: 147.4 g Power supply: 24 VDC @ 400 mA

You can refer to products genuine fire alarm equipment...HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Notifier HS-NCM high-speed network control module

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.13483 sec| 4333.516 kb