Detailed Description Notifier Control Panel, Active Repeater IDR-2A

The IDR2A Active Repeater will repeat the LCD & LED indication on the main fire alarm panel and allow the operator to command the system, using the system control knobs (Mute, Accept, Evacuate, Sound). silence, Sound Reverberation and Reset). Furthermore, the IDR2A has test and configuration functions such as Normal Message editing, Light Test, LCD Test, Buzzer Test and Button Test option. For added security, a push button on the front of the repeater enables/disables certain push buttons. Nine LEDs provide a quick summary of general system status to the user. Compact design makes it easy to install and operate IDR Series repeaters. The repeater event log can store up to 150 most recent events; This also supports operations.

Bảng điều khiển Notifier, Bộ lặp hoạt động IDR-2A

Mechanical Specifications Control Panel Notifier, Active Repeater IDR-2A

• Dimensions Height: 165 mm Width: 254 mm Depth: 50 mm

• Weight: 1.7 Kg (approx.)

• Material: Light steel plate shell

• Maximum Wire Gauge for Terminals: 0.5mm2 to 2.5mm2

Electrical Specifications Control Panel Notifier, Active Repeater IDR-2A

• Operating voltage: 18-32V dc

• Static current: 90mA

• Alarm current: 120mA (-2P / -2A), 155mA (-6A)

• Media: RS485 . 2-wire serial link

• Selectable address range in the range 0-31 (0 unattended and unused except during power-up testing)

Environmental parameters Notifier Control Panel, Active Repeater IDR-2A

• Operating temperature range: -5°C to +45°C

• Humidity: Relative humidity 5 to 95% (non-condensing)

• Panel sealing: IP 30, (EN 60529)

• Vibration: EN 60068-2-6 , 10-150Hz at 0.981ms-2 (Meets the requirements of EN 54-2/4)

• EMC emissions: EN 50081-1Immunity: EN 50130-4

• Safety: EN 60950

You can refer to products genuine fire alarm equipment...HERE

 

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Notifier Control Panel, Active Repeater IDR-2A

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13726 sec| 4319.492 kb