Notifier Control Module,IDR-CM and IDR-CME Compact Emulation Driver

Manufacture: Notifire
Product code: IDR-CM

Notifier control module, IDR-CM & IDR-CME compact simulation driver
⭐ Notifier fire alarm equipment, UK fire alarm equipment, 24/7 free technical consultation , Notifier smoke detector price

Zalo

Consulting hotline: 0944934114
Product information

Detailed Description of Notifier Control Module,IDR-CM and IDR-CME Compact Emulation Driver

Compact Mimic is an expandable simulator suitable for standard or more complex applications where mimic displays are required in conjunction with NOTIFIER fire control panels. Common fire, fault, test and de-noise outputs and OK outputs can be configured in conjunction with a lockout input to enable evacuation, silence, light test, mute, and reset input. The Compact Mimic comes in two types of boards: the main board (IDR-CM) and the expansion board (IDR-CME), both of which can have up to 16 configurable outputs. A fully utilized compact simulation system can consist of one main board and up to 9 expansion boards, providing a total of up to 160 configuration outputs.

Module điều khiển Notifier,Trình điều khiển mô phỏng nhỏ gọn IDR-CM & IDR-CME

 Specifications Notifier Control Module,IDR-CM and IDR-CME Compact Emulation Driver

• IDR-CM Panel Dimensions:

- Height: 25mm

- Length: 102 mm

- Height: 152 mm

• IDR-CME Expansion Board Dimensions:

- Height: 25mm

- Length: 44 mm

- Length: 152 mm

• Maximum wire gauge for terminals: 0.5mm2 and 2.5mm2

The IDR-CM control board has a general fault, OK power supply, test LED, and general test. There are 16 LED or relay outputs that can be configured out of the box (like all burning or 8 burning and 8 fault/test/off, both starting some specified area) or individually via via the offline configuration tool. Provisioning is made for Evacuation, Silent Sound, Light Check, Button Mute and Reset, and for a level 2 access key. Expandable with up to 9 IDR-CME expansion boards , each offering 16 additional configurable outputs, providing up to 160 output configurations in total

Electrical Notifier Control Module,IDR-CM and IDR-CME Compact Emulation Driver

• Operating voltage: 18-30Vdc

• Current Consumption: IDR-CM Panel: 35mA max.IDR-CME Expansion Board: 0.5mA max.

• Individual active output current: Configured for LEDs limited to 6mA. .

• CommunicationsMedium: RS485 2-wire serial link: Functions at 42VBaud: 1200 Baud Max. Cable length: 3000m RS485 . network

Environmental parameters Notifier Control Module,IDR-CM & IDR-CME Compact Emulation Driver

• Operating temperature -5°C to +45°C

• Relative humidity: 15% to 95%, non-condensing

• EMC emissions: EN 50081-1Immunity: EN 50130-4 • Safety: EN 60950

You can refer to products genuine fire alarm equipment...HERE

 

 

 

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Notifier Control Module,IDR-CM and IDR-CME Compact Emulation Driver

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.16637 sec| 4341.813 kb