N-ANN-LED and N-ANN-80 Notifier reporting module
The gst fire alarm catalog quote
⭐N-ANN-Series offers a comprehensive range of accessories, relay modules and drivers to interface with compatible fire alarm control panels. and report problems, system errors, 12 months warranty, 24/7 technical advice, Provide gst smoke detectors, gst fire alarms, gst beam detectors, gst i 9105r fire alarm beams , document: how to connect gst fire alarm cabinet, gst 8 zone fire alarm center, gst 4 zone fire alarm cabinet
The N-ANN-LED and N-ANN-80 Reporters replicate common system failures and input zones/points when used with a compatible fire alarm control panel. The N-ANN-I/O is an LED driver module that can be used in a variety of applications, including interface with FACP to control most custom graphics engines. The N-ANN-RLY relay module provides 10 programmable Form-C relays when used with FACP.
⭐ Features and benefits
N-ANN-LED
- Includes three LEDs for each zone: Alarm, Incident and Monitoring
- N-ANN-RLED includes all red LEDs for alarm indication
- Compatible with NFW-50(C), NFW2-100(C), SFP-5UD(C), SFP-10UD(C), RP-2001(C), RP-2002(C)
N-ANN-80
- Backlit 80 character LCD display (20 characters x 4 lines)
- Up to eight N-ANN-80s can be connected on the ANN-
- Control switches for System Confirm, Signal Silence, Drill and Reset
- Displays device type identifiers, individual point alarms, breakdowns, monitoring, zones and custom alpha labels
N-ANN-RLY
- Connects to ANN-BUS terminals on FACP and requires minimal programming
- Ten Form-C relays can be programmed for different functions; Alarms, Faults, Monitoring, AC Loss, Waterline Delays, Inlet Areas, and Receiverable Alarms
- Up to eight ANN-BUS devices can be connected to the ANN-BUS of each FACP
N-ANN-I / O
- Connects to ANN-BUS terminals on FACP and requires minimal programming
- Each N-ANN-I/O module controls up to 40 LEDs
⭐ Thông số kỹ thuật
N-ANN-LED
- Maximum ANN-BUS voltage: 24 VDC
- Maximum current: Alarm: 68 mA Standby: 28 mA
- Maximum wiring distance FACP: 6,000 ft. (1,829 m.)
N-ANN-80
- Operating voltage range: 18 VDC to 28 VDC.
- Current consumption @ 24 VDC nominal (filtered and irreparable): 40 mA max.
N-ANN-RLY
- Maximum ANN-BUS voltage: 24 VDC
- Maximum current: Alarm: 75 mA Standby: 15 mA
N-ANN-I / O
- Maximum ANN-BUS voltage: 24 VDC
- Maximum current: Alarm: 200 mA, Standby: 35 mA, Each LED: 10mA
- Maximum wiring distance FACP: 6000 ft. (1829 m.)
⭐ Danh sách tiêu chuẩn
N-ANN-LED
- UL: S635
- ULC: S635 (N-ANN-LED only)
- FM approved
- CSFM: 7120-0028: 0259
- MEA: 333-07-E
- NY Fire Department: COA # 6177
N-ANN-80
- UL: S635
- FM approved
- CSFM: 7120-0028: 240
- MEA: 442-06-E
N-ANN-RLY
- UL: S635
- FM approved
- New York Fire Department: #COA 6177
- CSFM: 7165-0028: 0245; 7165-0028: 0246
N-ANN-I / O
- UL: S635
- CSFM: 7120-0028: 242
- MEA: 442-06-E
You can refer to products genuine fire alarm equipment...HERE
You will receive a quote from us as soon as possible..