⭐N-ANN-Series offers a comprehensive range of accessories, relay modules and drivers to interface with compatible fire alarm control panels. and report problems, system errors, 12 months warranty, 24/7 technical advice, Provide gst smoke detectors, gst fire alarms, gst beam detectors, gst i 9105r fire alarm beams , document: how to connect gst fire alarm cabinet, gst 8 zone fire alarm center, gst 4 zone fire alarm cabinet

Zalo

Consulting hotline: 0944934114
Product information

The N-ANN-LED and N-ANN-80 Reporters replicate common system failures and input zones/points when used with a compatible fire alarm control panel. The N-ANN-I/O is an LED driver module that can be used in a variety of applications, including interface with FACP to control most custom graphics engines. The N-ANN-RLY relay module provides 10 programmable Form-C relays when used with FACP.

Module báo cáo Notifier N-ANN-LED và N-ANN-80

⭐ Features and benefits

N-ANN-LED

- Includes three LEDs for each zone: Alarm, Incident and Monitoring

- N-ANN-RLED includes all red LEDs for alarm indication

- Compatible with NFW-50(C), NFW2-100(C), SFP-5UD(C), SFP-10UD(C), RP-2001(C), RP-2002(C)

N-ANN-80

- Backlit 80 character LCD display (20 characters x 4 lines)

- Up to eight N-ANN-80s can be connected on the ANN-

- Control switches for System Confirm, Signal Silence, Drill and Reset

- Displays device type identifiers, individual point alarms, breakdowns, monitoring, zones and custom alpha labels

N-ANN-RLY

- Connects to ANN-BUS terminals on FACP and requires minimal programming

- Ten Form-C relays can be programmed for different functions; Alarms, Faults, Monitoring, AC Loss, Waterline Delays, Inlet Areas, and Receiverable Alarms

- Up to eight ANN-BUS devices can be connected to the ANN-BUS of each FACP

N-ANN-I / O

- Connects to ANN-BUS terminals on FACP and requires minimal programming

- Each N-ANN-I/O module controls up to 40 LEDs

⭐ Thông số kỹ thuật

N-ANN-LED

- Maximum ANN-BUS voltage: 24 VDC

- Maximum current: Alarm: 68 mA Standby: 28 mA

- Maximum wiring distance FACP: 6,000 ft. (1,829 m.)

N-ANN-80

- Operating voltage range: 18 VDC to 28 VDC.

- Current consumption @ 24 VDC nominal (filtered and irreparable): 40 mA max.

N-ANN-RLY

- Maximum ANN-BUS voltage: 24 VDC

- Maximum current: Alarm: 75 mA Standby: 15 mA

N-ANN-I / O

- Maximum ANN-BUS voltage: 24 VDC

- Maximum current: Alarm: 200 mA, Standby: 35 mA, Each LED: 10mA

- Maximum wiring distance FACP: 6000 ft. (1829 m.)

⭐ Danh sách tiêu chuẩn

N-ANN-LED

- UL: S635

- ULC: S635 (N-ANN-LED only)

- FM approved

- CSFM: 7120-0028: 0259

- MEA: 333-07-E

- NY Fire Department: COA # 6177

N-ANN-80

- UL: S635

- FM approved

- CSFM: 7120-0028: 240

- MEA: 442-06-E

N-ANN-RLY

- UL: S635

- FM approved

- New York Fire Department: #COA 6177

- CSFM: 7165-0028: 0245; 7165-0028: 0246

N-ANN-I / O

- UL: S635

- CSFM: 7120-0028: 242

- MEA: 442-06-E

You can refer to products genuine fire alarm equipment...HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about N-ANN-LED and N-ANN-80 Notifier reporting module

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.14895 sec| 4341.633 kb