ID3000, Control center module 2 loops - 8 loops

Manufacture: INGESCO
Product code: ID3000

ID3000 : Control center module 2 rounds - 8 rounds r Catalog of notifier fire alarms
⭐price list of smoke detectors notifiers, notifiers of fire alarm modules ,Supply of n6000 fire alarm cabinets, genuine notifier dealers, Provide catalogs china fire extinguisher, fire cabinet catalog , Consulting : user manual of notifier fire alarm cabinet, programming guide of notifier fire alarm cabinet , Quotation of push button address notifire, smoke detector notifier fsp-851 , Price Common smoke detector notifier, addressable smoke detector fsp 851 , Smoke detector quote. addressable heat detector notifier, smoke detector honeywell, Provide all kinds of monitoring module address notifier, fire alarm notifier, User manual of notifie fire alarm software

Zalo

Consulting hotline: 0944934114
Product information

Description

- The configurable modular system is designed and engineered to adapt the equipment to the needs or requirements of a fire protection installation. It has different cards to expand the capacity of the system, several power supply models and different formats and sizes of cabins. The ID3000 is an analog and algorithmically processed modular hub for fire detection and alarm, individual monitoring and control of system elements. With CPD EN54 part 2 and 4 certificate. The ID3000 control board has 2 loops, expandable to 8 by expansion cards with 2 analog detection loops. It has a micro-processed ring tag that allows working in degraded mode, which exceeds the requirements of the EN54 standard. 4 configurable and programmable output circuits, 2 24 Vdc outputs for powering external equipment, 2 programmable input circuits, and 255 zones.

- Each loop can control up to 99 smart analog detectors, plus 99 display (input) or control (output) modules, for a total of 198 individual identification points per loop. Includes insulating rings at the input and output of the loop wire. It can power sirens and lightning detectors through the SLC loop itself (according to specs). It features a 240 x 64 pixel LCD liquid crystal graphic display (6 lines of 40 alphanumeric characters), a membrane-protected keypad with access keys for controlling keys and functions, and LEDs for display. system status display.

- Available in different formats and sizes of cabs with power supplies 3 to 7 A, to meet, at all times, the requirements of the EN54-14 standard for system capability and autonomy.

- Battery capacity: ref 020-472-009, 2 x 12Vdc. 12 hours and reference 020-474-009, 2 x 12Vdc. 26 Ah.

• Power supply: 230V, 50Hz

• Current Consumption: 1.6A

• Maximum alarm output current: 3A

• Auxiliary power output: 26 - 28Vdc / 150mA

• Analog loop output: 22.5 - 26.4Vdc / 0.5A (see battery and loop calculation program)

• Relay contact: 30V / 1A

• Operating temperature: -5ºC to 45ºC (recommended + 5ºC to 35ºC)

• Relative humidity: +5% to 95%

• Protection index: IP30

• Weight: 14 Kg. (without battery)

• Dimensions in mm (standard cab): 500 (width) x 400 (height) x 153 (depth)

• With CPD certificate: 0786-CPD-20878 EN54 part 2 and 4.

- It incorporates AWACS algorithms to control and manage signals VIEW and SMART laser sensors and software to control sensor sensitivity and actions at different times of day.

- Opto isolation interface 020-479 allows connection of remote repeaters 002-452-001. The 020-478 isolated interface, with many configurable protocol options, allows integration to control external 80-character systems, graphics programs and printers.

- The ID3000 exchange can operate in a network:

- The ID2net network allows connection of up to 63 NOTIFIER fire alarm control panels of the ID3000 Series, for a total of 504 loops (99,792 individual identification points). Each control panel (node ​​in the network) maintains its own protection zone, while monitoring and controlling other areas (other nodes in the network).

- The ID2net network is based on proven ARCNET local area network technology, with more than 4 million nodes installed worldwide. The network has neither master nor slave hub as all are equal in the network (peer-to-peer network). The protocol is bidirectional with one token, thus avoiding collisions during transmission. There are priority messages to ensure alarms are received in less than 0.5 seconds.

- In the case of a closed loop configuration, if a single wire break occurs, communication continues to exist on all nodes; If more disruptions occur, communication exchange groups will act as subnets.

You can refer to products genuine fire alarm equipment...HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about ID3000, Control center module 2 loops - 8 loops

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.13341 sec| 4341.797 kb