V-HFD Intelligent Smoke Detector

Manufacture: kidde
Product code: V-HFD

Kidde brand intelligent analog detectors are meticulously engineered to deliver high-perfor mance features, superb reliability, and unbeatable quality. With their highly stable design, these detectors resist air movement caused by heating and air conditioning, making them reliable performers ideally suited to modern building interiors. The installation and maintenance advantages of Kidde brand intel ligent detectors add value throughout their service life. The twist-and-lock design makes short work of installation and maintenance operations. A plastic breakout on the detector housing optionally prevents removal the base except with a special tool. A bright, easy-to-see LED flashes red when the detector is in alarm, thus eliminating much of the guesswork when responding to front-panel indications.

•The V-HFD is fixed-temperature heat detector with an alarm threshold of 135
° F (57
° C).

• The V-HRD is a rate-of-rise heat detector calibrated for 15
°F (8
°C) per minute.

• The V-PHS houses an optical sensing chamber that detects smoke, as well as a fixed-temperature sensor that detects heat. The detector analyzes data both sensors to determine when an alarm is initiated.

•The V-PS houses an optical sensing chamber that detects smoke. All detectors feature comprehensive self-diagnostic capability. V-PS and V-PHS optical detectors continuously adjust their sensitivity to compensate for changes in the environment such as the presence of dirt, smoke, temperature, and humidity. These detectors issue a dirty sensor warning when they reach their preset limit

Zalo

Consulting hotline: 0944934114
Product information

Standard Features

Note: Some features described here may not be supported by all control systems. Check your control panel’s Installation and Operation Guide for details.

• Next generation optical smoke sensing technology

• Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration

• Uses Existing Wiring

• Automatic Device Mapping

• Up To 250 Total Addresses Per Loop

• Two Levels of Environmental Compensation

• Two Levels of Dirty Detector Warning

• Twenty Pre-Alarm Settings

• Five Sensitivity Settings

• Non-Volatile Memory

• Electronic Addressing

• Identification of Dirty or Defective Detectors

• Automatic Day/Night Sensitivity Adjustment

• Bicolor (Green/Red) Status Led

• Standard, Relay, Fault Isolator, and Audible Mounting Bases

• Sensor Markings Provide Easy Testing Identification

Application

The KI-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its highperformance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings.

Standard Detector Base, KI-SB, KI-SB4

This is the basic mounting base for Kidde KI Series detectors. The GSA-LED Remote LED is supported by this Base

KI-PD Intelligent Smoke Detector

Isolator Detector Base, KI-IB, KI-IB4

This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED.

The isolator operates as follows:

- a short on the line causes all isolators to open within 23 msec

- at 10 msec intervals, beginning on one side of the class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power

- when the isolator next to the short closes, it reopens within 10 msec.

The process repeats beginning on the other side of the loop controller.

KI-PD Intelligent Smoke Detector

Audible Sounder Bases, Fire Mode

AB4GT, AB4G, AB4G-LF sounder bases

KI-PD Intelligent Smoke Detector

Dimensions

KI-PD Intelligent Smoke Detector

Specifications

Operating voltage 15.20 to 19.95 VDC
Normal operating current 51 µA
Alarm current 68 µA
Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Vibration level 10 to 35 Hz, with an amplitude of 0.01 in.10 to 35 Hz, with an amplitude of 0.01 in.
Air velocity 0 to 4,000 ft./min (0 to 20 m/s)
Wall mounting 12 in. (305 mm) max. ceiling
Compatible bases See Ordering Information
Compatible detector testers Testifire 1000, Testifire 2000
Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Construction High Impact Engineering Polymer, White
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Agency Listings CAN/ULC-S529, UL 268, UL 268A

Ordering Information

Catalog Number Descriptio Ship Wt. lbs (kg)
KI-PD Intelligent Optical Smoke Detector 0.4 (0.16)

Accessories

KI-SB Detector Mounting Base - Standard 0.2 (.09)
KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt
KI-RB Detector Mounting Base w/Relay
KI-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt
KI-IB Detector Mounting Base w/Fault Isolator
KI-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt
GSA-LED Remote Alarm LED (not for EN54 applications)
KI-ABST Audible (Sounder) Base for Fire Detectors 0.3 (0.15)
KI-ABLT Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
KI-ABDT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
GSA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04)
GSA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04)
GSA-DMP Detector Mounting Plate 3.0 (1.4)

Ordering Information

Model Description Ship Wt: Ib, (kg)
V-PHS Intellgent Analog Optical/Fixxed Temperature Detector 0,25 (0,11
V-PS Intellgent Analog Optical Smoke Detector
V-HRD Intellgent Analog Rate-of-Rise Heat Detector
V-HFD Intellgent Analog Fixxed Temperature Detector
B4U Standard Base 0.11(0.05)
RB4U Relay Detector Base
IB4U Isolator Detector Base
SB4U Audible (Sounder) Detector Base
SB4U-LF Audible (Sounder) Detector Base, Low Frequency Output)
AB4G-SB Surface Box for Audible Base 1.0(0.45)
GSA-LED Remote alarm LED, use with standra base only 0/2(0.09)
211-10PKG Replancement optical chambers (package of 10) 0,25 (0,11
Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about V-HFD Intelligent Smoke Detector

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.14374 sec| 4357.227 kb