✅ The actual operation of the GSA-CC1S is determined by the “personality code” selected by the installer, which is downloaded to the module the Signature loop controller during system configuration. Depending on their assigned personality, Synchronization Output Modules may be used as a signal power riser selector to provide synchronization of fire alarm signals across multiple zones, or for connecting, upon command the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to operate audible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter’s telephones.

Zalo

Consulting hotline: 0944934114
Product information

Standard Features

• Provides UL 1971-compliant auto-sync output for visual signals Use for connecting a supervised output circuit to a supervised 24 Vdc riser input and synchronizing multiple notification appliance circuits.

• Functions as an audible signal riser selector Use as a synch module or for connecting supervised 24 Vdc Audible/Visible signal circuits, or 25 and 70 VRMS Audio Evacuation and Telephone circuits to their power inputs.

• Built-in ring-tone generator When configured for telephone circuits, the GSA-CC1S generates its own ring-tone signal, eliminating the need for a separate ring-tone circuit.

• Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop.

• Electronic addressing Programmable addresses are downloaded the loop controller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set.

• Intelligent device with microprocessor All decisions are made at the module to allow lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required.

Application

The GSA-MCC1S is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-CC1S, but takes advantage of the modular flexibility and easy installation that characterize all UIO modules. Two- and six-module UIO motherboards are available. These can accommodate individual risers for each on-board module, or risers that are shared by any combination of its UIO modules. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures.

Installation

GSA-MCC1S: mount the UIOxR motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the module any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIOxR motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2 ) wire size.

MCC1S Synchronization Output Module

MCC1S Synchronization Output Module

MCC1S Synchronization Output Module

 

 

Specifications

Catalog Number GSA-CC1S GSA-MCC1S
Mounting North American 2½ inch (64 mm) deep two-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 2-gang covers and GSA-MP mounting plates Plugs UIO2R, UIO6R or UIO6 Motherboards
Description Synchronization Output Module
Type Code 50 (factory set)
Address Requirements Uses one module address
Wiring Terminations Suitable for #12 to #18 AWG (2.5 mm² to 0.75mm²
Operating Current

Standby = 223µA

Activated = 100µA

Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Output Rating

24 Vdc = 2 amps

25 V Audio = 50 watts

70 V Audio = 35 watts

Construction High Impact Engineering Polymer
Storage and Operating Environment

Operating: 32°F to 120°F (0°C to 49°C)

Storage: -4°F to 140°F (-20°C to 60°C)

Humidity: 0 to 93% RH

LED Operation Green LED - Flashes when polled Red LED - Flashes when in alarm/ active
Compatibility Use with: Signature Loop Controller
Agency Listings UL, ULC, CSFM, MEA

Ordering Information

Catalog Number Description Shipping Wt. lbs (kg)
GSA-CC1S Synchronization Output Module (Standard Mount) - UL/ULC Listed 0.5 (0.23)
GSA-MCC1S Synchronization Output Module (UIO Mount) - UL/ULC Listed 0.18 (0.08)

Related Equipment

27193-21 Surface Mount Box - Red, 2-gang 2 (1.2)
27193-26 Surface Mount Box - White, 2-gang 2 (1.2)
GSA-UIO2R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15)
GSA-UIO6R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28)
GSA-UIO6 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25
235196P Bi-polar Transient Protector 0.01 (0.05)
MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1)
GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70)
GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23)
GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46)
Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about MCC1S Synchronization Output UIO (Plug-in) Module

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.14827 sec| 4353.094 kb