Intelligent Multisensor Smoke and CO Detector KI-PCD

Manufacture: kidde
Product code: KI-PCD

The KI-PCD detector brings advanced multisensor technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. The KI-PCD provides a combination of optical detection for the early detection of smoke, with the added element of carbon monoxide sensing. The result is a detector that pulls double duty: continually monitoring the environment for signs of fire — as well as its invisible yet deadly companion: carbon monoxide. Like all KI Series detectors, the KI-PCD gathers analog information its sensing elements and converts this data digital signals. To make an alarm decision, the detector’s on-board microprocessor measures and analyzes smoke sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. The detector also analyzes the smoke sensor independently the CO sensor to determine whether to initiate a fire alarm, a life safety CO alarm, or both

Zalo

Consulting hotline: 0944934114
Product information

Standard Features

Note: Some features described here may not be supported by all control systems. Check your control panel’s Installation and Operation Guide for details.

• Next generation detection technology

• Integrates optical smoke with carbon monoxide detection

• Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration

• Sensor Markings Provide Easy Testing Identification

• Uses existing wiring

• Automatic device mapping

• Ground fault detection by module

• Up To 250 Total Addresses Per Loop

• Two levels of environmental compensation

• Two levels of dirty detector warning

• Up to twenty pre-alarm settings

• Five sensitivity settings

• Non-volatile memory

• Electronic addressing

• Environmental compensation

• Automatic day/night sensitivity adjustment

• Bicolor (green/red) status LED

• Standard, relay, fault isolator, and audible mounting bases

Application Smoke detection

The KI-PCD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its highperformance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings.

CO Detection

Monitored CO detection, such as that provided by the KI-PCD, is becoming mandated with increasing frequency in all types of commercial applications, but particularly in occupancies such as hotels, rooming houses, dormitories, day care facilities, schools, hospitals, assisted living facilities, and nursing homes. Known as the “Silent Killer,” CO is odorless, tasteless, and colorless. It claims nearly 500 lives, and results in more than 15,000 hospital visits annually.

Dimensions

Intelligent Multisensor Smoke and CO Detector KI-PCD

Specifications

Operating voltage 15.20 to 19.95 VDC
Normal operating current 51 µA
Alarm current 68 µA
Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Vibration level 10 to 35 Hz, with an amplitude of 0.01 in.
Wall mounting 12 in. (305 mm) max. ceiling
Compatible bases See Ordering Information
Compatible detector testers Testifire 1000, Testifire 2000
Operating environment 32 to 120°F (0 to 49°C), 0 to 90% RH, noncondensing
Construction High Impact Engineering Polymer, White
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic

UL CO alarm level

per UL 2034, CAN/CSA 6.19

 

70 ppm 60 to 240 minutes

150 ppm 10 to 50 minutes;

400 ppm 4 to 15 minutes

UL CO false alarm level

per UL 2034, CAN/CSA 6.19

30 ppm 30 days

70 ppm 60 minutes

Agency Listings,

KI-PCD

UL 268, UL 2075. Evaluated to the CO alarm sensitivity limits of UL

2034. ULC Listed to CAN/ULC-S529 and CAN/CSA 6.19.

Ordering Information

Catalog Number Description Ship Wt. lbs (kg)
KI-PCD Multisensor Smoke and CO Detector 0.4 (0.16)

Compatible Bases

KI-SB Detector Mounting Base - Standard 0.2 (.09)
KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt
KI-RB Detector Mounting Base w/Relay
KI-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt
KI-IB Detector Mounting Base w/Fault Isolator
KI-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt
GSA-LED Remote Alarm LED (not for EN54 applications)
KI-ABLT Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
KI-ABDT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
GSA-T3T4 Tone Generator for Detector Sounder Bases with CO mode 0.2 (0.1)
GSA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (.04)

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Intelligent Multisensor Smoke and CO Detector KI-PCD

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.15400 sec| 4356.859 kb