Harsh Environment Strobes CS405-7A-8A
MS Series ✔️
✅ strobes are specially designed for use with compatible life safety communication and control equipment to alert the hearing impaired of a life safety event ✔️
✅ Strobes are available with 15 cd, 15/75 cd, 30 cd, 60 cd, and 110 cd effective flash intensity. They are fully compatible with Genesis signal
- 4MS Series strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a separately-installed EG1M Signal Master, or GSA-CC1S Synchronization Module, or when powered by suitably enabled booster power supplies and control panels.
- The flash 4MS Series strobes can be noticed almost any position in the room, corridor, or large open space. 4MS Series strobes are UL 1971 listed with both wall and ceiling cd intensity ratings (see Specifcations). This is useful in areas where the Authority Having Jurisdiction (AHJ) permits ceiling-mount strobes.
- 4MS Series strobes are designed for 16 to 33 Vdc operation and must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to allow full signal circuit supervision and polarized connections are made to terminals that accept up to #12 AWG (2.5mm²) wire.
- The strobe front plate is of steel construction fnished with durable baked epoxy polyester powder-coat paint.
Standard Features
• UL 1971-listed synchronizing strobe
- Integrity strobes synchronize to the latest UL 1971 requirements when used with a synchronization source.
• Genesis-compatible
- All Genesis and Integrity strobes on the same circuit meet UL 1971 synchronization requirements when used with an external control module.
• Approved for public and private mode applications
- UL 1971-listed as signaling devices for the hearing impaired and UL 1638-listed as protective visual signaling appliances.
• Rugged red or white steel front plate
- Ideal for outdoor or harsh environments.
• Rated for wall or ceiling installation
• Field changeable feld markings
Lens language or standard “FIRE” marking is easily changed with optional LKW and LKC series lens kits.
• Fits 4-inch square flush box
- Ideal for retroft and renovation projects.
• UL/ULC rated outdoor option
Application
- Kidde strobes are UL 1971-listed for use indoors as wall-mounted public-mode notifcation appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed specifed levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details.
- As part of the Enhanced Integrity line of products, 4MS Series strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important because a small portion of the population have a condition which may cause them to become disoriented multiple random flashes of light. Integrity strobes minimize this risk.
- Integrity strobes are fully compatible with Kidde Genesis signals
Installation and Mounting
All models ft to a standard flush mounted, North American four inch electrical box, 1-1/2 inch (38 mm) deep minimum. Optional Kidde weatherproof, surface mount boxes are available. The strobes must be connected to signal circuits which output a constant (not pulsed) voltage. Kidde recommends that these strobes always be installed in accordance with the latest recognized edition of national and local fre alarm codes.
Specifcations
Catalog Number |
4MS-5A |
4MS-3A |
4MS-6A |
4MS-7A, CS405-7A |
4MS-8A, CS405-8A |
UL 1638/ULC S526 |
15cd | 30cd | 60cd | 15/75cd | 110cd |
UL 1971 Rated Strobe |
15cd |
30cd wall |
60cd wall |
15cd wall |
110cd wall |
Strobe Flash Rate |
Synchronized at one flash per second. External control module necessary to meet UL 1971 synchronization requirements of |
||||
Synchronization Sources |
MEG1M-RM, GSA-CC1S, GSA-MCC1S, MIRBPS6, MIRBPS10 |
||||
Strobe Operating Volts |
Continuous 16 to 33 Vdc or 16 to 33 Vfwr |
||||
Operating Environment |
INDOOR: 30º C @ 85% RH; 32 - 120º F (0 - 49º C) ambient temperature. |
||||
Lens Markings |
Supplied with LKW-1 “FIRE” red letters, vertical both sides (Wall Mount) |
||||
Wire Connections |
Terminals - polarized input, #12 AWG (2.5mm²) max wire size |
||||
Flash Tube Enclosure |
Clear LEXAN |
||||
Strobe Plate, Finish |
CRS steel - 5½ in (140mm) square, red or white baked epoxy polyester powder-coat fnish |
||||
Mounting |
INDOOR: North American 4 in square electrical box; |
||||
Agency Listings |
UL 1971, UL 1638, ULC S526, CE, FM, CSFM, MEA (All models comply with ADA Code of Federal Regulation Chapter 28 |
Ordering Information
Catalog |
Description |
Ship Wt. lb (kg) |
4MS-5AR |
Strobe, 15 cd, Red |
1 (0.4) |
4MS-5ARW | Strobe, 15 cd, White | |
4MS-7AR | Strobe, 15 cd/75, Red | |
4MS-7ARW | Strobe, 15 cd/75, White | |
4MS-3AR | Strobe, 30 cd, Red | |
4MS-3ARW | Strobe, 30 cd, White | |
4MS-6AR | Strobe, 60 cd, Red | |
4MS-6ARW | Strobe, 60 cd, White | |
4MS-8AR | Strobe, 110 cd, Red | |
4MS-8ARW | Strobe, 110 cd, White |
Outdoor Listed Strobes
Outdoor Listed Strobes |
||
CS405-7A |
Strobe, 15/75, Outdoor, Red |
1 (0.4) |
CS405-8A |
Strobe, 110cd, Outdoor, Red |
Synchronization Sources |
||
EG1M-RM |
Genesis Signal Master Remote Mount (1-gang) |
0.2 (0.1) |
GSA-CC1S |
Synchronization Output Module (Standard Mount) - UL/ULC |
0.5 (0.23) |
GSA-MCC1S |
Synchronization Output Module (UIO Mount) - UL Listed |
0.18 (0.08) |
MIRBPS6A |
6.5 Amp Booster Power Supply |
13 ( 5.9) |
MIRBPS10A |
10 Amp Booster Power Supply |
13 ( 5.9) |
APS6A |
6.5 Amp Auxiliary Power Supply |
26 (11.8) |
APS10A |
10 Amp Auxiliary Power Supply |
26 (11.8) |
Mounting Accessories