GSA-MCT2 Dual Input UIO (Plug-in) Module

Manufacture: kidde
Product code: GSA-MCT2

The GSA-MCT2 ⭐
✅  is part of the UIO family of plug-in signature Series modules. It functions identically to the GSA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures.

Zalo

Consulting hotline: 0944934114
Product information

Standard Features

• Multiple applications Including Alarm, Alarm with delayed latching (retard) for waterflow applications, Supervisory, and Monitor. The installer selects one of four “personality codes” to be downloaded to the module through the loop controller.

• GSA-CT1HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors.

• Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module.

• Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop.

• Electronic addressing Programmable addresses are downloaded the loop controller, a PC, or the Signature Program/Service Tool. There are no switches or dials to set.

• Ground fault detection by address Detects ground faults right down to the device level.

GSA-CT1 Single Input Module (One-gang standard mount)

Application

The duty performed by the  GSA-MCT2 is determined by their sub-type code or “Personality Code”. The code is selected by the installer depending upon the desired application and is downloaded the loop controller. One personality code can be assigned to the GSA-MCT2. Two personality codes can be assigned to the GSA-MCT2 Codes 1, 2, 3 and 4 can be mixed on GSA-MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B).

Installation

GSA-MCT2: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the GSAMCT2 any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2 ) wire size.

GSA-MCT2 Dual Input UIO (Plug-in) Module

 

Specifications

Catalog Number GSA-CT1HT GSA-CT1 GSA-CT2 GSA-MCT2
Description Single Input Module Dual Input Module
Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available
Address Requirements Uses One Module Address Uses Two Module Address
Operating Current

Standby = 250µA;

Activated = 400µA

Standby = 396µA;

Activated = 680µA

Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Construction High Impact Engineering Polymer
Mounting North American 2½ inch (64 mm) deep one-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with one-gang covers and GSA-MP mounting plates UIO2R/6R/6 Motherboard
Operating Environment

32°F to 158°F

(0°C to 70°C)

32°F to 120°F (0°C to 49°C)
Storage Environment 4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH
LED Operation

On-board Green LED - Flashes when polled; On-board Red LED

- Flashes when in alarm/active.

Both LEDs - Glow steady when in alarm

Compatibility Use with Signature Loop Controller
Agency Listings UL, ULC, MEA, CSFM

Ordering Information

Catalog Number Description Ship Wt. lbs (kg)
GSA-CT1 Single Input Module — UL/ULC Listed 0.4 (0.15)
GSA-CT1HT Single Input Module High Teperature Operation UL/ULC Listed
GSA-CT2 Dual Input Module — UL/ULC Listed
GSA-MCT2 Dual Input Plug-in (UIO) Module — UL, ULC Listed 0.1 (0.05)

Related Equipment

27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6)
27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6)
GSA-UIO2R

Universal Input-Output Module Board w/Riser Inputs

— Two Module Positions

0.32 (0.15)
GSA-UIO6R

Universal Input-Output Module Board w/Riser Inputs

— Six Module Positions

0.62 (0.28)
GSA-UIO6 Universal Input-Output Module Board — Six Module Positions 0.56 (0.25)
MFC-A

Multifunction Fire Cabinet

— Red, supports Signature Module Mounting Plates

7.0 (3.1)
GSA-MB4

Transponder Mounting Bracket (allows for mounting

two 1-gang modules in a 2-gang box)

0.4 (0.15)
GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70)
GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23)
GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46)
Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about GSA-MCT2 Dual Input UIO (Plug-in) Module

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.14311 sec| 4349.109 kb