GSA-CC2 Dual Input (Riser) Signal Module

Manufacture: kidde
Product code: GSA-CC2

GSA-CC2 Single Input Signal Modules is part of Kidde's Signature Series system ⭐
✅ They are intelligent analog addressable devices used for connecting, ⭐
✅ upon command the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to operate audible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter’s telephones. The actual operation of the GSA-CC2 is determined by the “personality code” selected by the installer. It is downloaded to the module the Signature loop controller during system configuration.

Zalo

Consulting hotline: 0944934114
Product information

The GSA-CC2 mount to standard North American two-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module.

Standard Features

• Single and Dual input (riser) Use for connecting supervised 24 Vdc Audible/Visible signal circuits, or 25 and 70 VRMS Audio Evacuation and Telephone circuits to their power inputs.

• Ring-tone generator When configured for telephone circuits, the GSA-CC1 generates its own ring-tone signal eliminating the need for a separate ring-tone circuit.

• Plug-in (UIO) or standard 2-gang mount UIO versions allow quick installation where multiple modules are required. The 2-gang mount version is ideal for remote locations that require a single module.

• Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop.

• Electronic addressing Programmable addresses are downloaded the loop controller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set.

• Intelligent device with microprocessor All decisions are made at the module to allow lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required.

• Ground fault detection by address Detects ground faults right down to the device level.

Application

The operation of the GSA-CC2 is determined by their sub-type code or “Personality Code”. The code is selected by the installer depending upon the desired application and is down-loaded the loop controller. Codes 5 and 6 apply to the GSA-CC1/MCC1 only. Code 7 is assigned to the GSA-CC2/MCC2 only and automatically applies to both circuits (A and B).

Installation

The GSA-CC1 and GSA-CC2: mount to North American 2-1/2 inch (64 mm) deep two-gang boxes and 1-1/2 inch (38 mm) deep 4-inch square boxes with two-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2 ) wire size.

GSA-CC2  Dual Input (Riser) Signal Module

 

GSA-CC2  Dual Input (Riser) Signal Module

Specifications

Catalog Number GSA-CC1 GSA-MCC1 GSA-CC2 GSA-MCC2
Description Single Input (Riser) Signal Module Dual Input (Riser) Signal Module
Type Code

50 (factory set) Two sub-types

(personality codes) are available

51 (factory set) One sub-type

(personality code) is available (factory set)

Address Requirements Uses one module address Uses two module addresses
Wiring Terminations Suitable for #12 to #18 AWG (2.5 mm² to 0.75mm²)
Mounting North American 2½ inch (64 mm) deep two-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 2-gang covers and GSA-MP mounting plates Plugs UIO2R, UIO6R or UIO6 Motherboards North American 2½ inch (64 mm) deep two-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 2-gang covers and GSA-MP mounting plates Plugs UIO2R, UIO6R or UIO6 Motherboards
Operating Current Standby = 223µA Activated = 100µA
Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Output Rating 24 Vdc = 2 amps 25 V Audio = 50 watts 70 V Audio = 35 watts
Construction High Impact Engineering Polymer
Storage & Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH
LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active
Compatibility Use with: Signature Loop Controller
Agency Listings UL, ULC, CSFM, MEA, FM

Ordering Information

Catalog Number Description Ship Wt. lbs (kg)
GSA-CC1 Single Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23)
GSA-MCC1 Single Input Signal Module (UIO Mount) - UL/ULC Listed 0.18 (0.08)
GSA-CC2 Dual Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23)
GSA-MCC2 Dual Input Signal Module (UIO Mount) - UL/ULC Listed 0.18 (0.08)

Related Equipment

27193-21 Surface Mount Box - Red, 2-gang 2 (1.2)
27193-26 Surface Mount Box - White, 2-gang 2 (1.2)
GSA-UIO2R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15)
GSA-UIO6R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28)
GSA-UIO6 Universal Input-Output Module Board - Six Module Positions 0.5 (0.23)
GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46

Accessories

MFC-A

Multifunction Fire Cabinet - Red, supports Signature

Module Mounting Plates

7.0 (3.1)
GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70)
GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23)
GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46)
Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about GSA-CC2 Dual Input (Riser) Signal Module

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.14999 sec| 4354.727 kb