Dual Input Module FX-IDC2B

Manufacture: kidde
Product code: FX-IDC2B

Kidde intelligent modules are engineered to deliver high-performance features, superb reliability ⭐
✅ and unbeatable quality. control of ancillary equipment, to enhanced signaling functionality, these products add flexibility and powerful options to Kidde intelligent systems

Zalo

Consulting hotline: 0944934114
Product information

- Designed expressly for small buildings, Kidde modules are addressable devices that are uniquely identified on the system by means of familiar rotary switches. Once registered, they share data and status information that determines how the system behaves and how connected devices interact with one another.

- Unique to Kidde modules is ground fault detection so precise that it actually pinpoints the specific module where the wiring problem has occurred. This saves hours of troubleshooting and wire tracing. And only Kidde provides this important feature!

- The Kidde family of intelligent modules also offers contractors and installers simple setup and installation, while delivering options that take full advantage of intelligent fire alarm processing. With a microprocessor in each device, intelligence is distributed throughout the system so that command decisions are made instantly at the individual module, rather than bottlenecking at the control panel.

- This not only speeds event processing, it also makes a more robust and reliable system – so robust, in fact, that when upgrading a conventional panel to a Kidde intelligent system, you can usually use existing wiring – no twisted or shielded cable required!

Standard Features

• Class A-B Two-Wire Module

- Acts as an interface between conventional two-wire smoke detectors and the Kidde control panel.

• Analog Class A Single Input Module

- Used to connect a normally open, alarm, supervisory, or monitor type dry contact initiating device circuit to the Kidde control panel.

• Analog Dual Input Module

- Connects two normally open, alarm, supervisory, or monitor type dry contact initiating device circuits to the Kidde control panel.

• Analog Dual Input Waterflow, Supervisory Module

- Used to connect normally open waterflow alarm and supervisory initiating device circuits to the Kidde control panel. For Class B circuit operation.

• Analog SLC Fault Isolator Module

- Protects a Class A SLC total collapse due to wire-to-wire short circuits.

• Analog NAC Module

- Connects a supervised output circuit to a signal riser.

• Analog Contact Relay Module

- Provides one Form C dry relay contact and can be configured to provide polarity reversal of its output.

• Analog Single Input Mini Module

- Connects a normally open, alarm, supervisory, or monitor type dry contact initiating device circuit (IDC) to the Kidde control panel. For Class B circuit operation.

Installation

Class A Single Input Module FX-IDC1A

Mount in a North American 4 inch square x 2-1/2 in. (64 mm) deep 2 gang box or a standard 4 in. square box 1-1/2 in. (38 mm) deep

Dual Input Module FX-IDC2B

- The FX-IDC2B connects two normally open, alarm, supervisory, or monitor type dry contact initiating device circuits (IDCs) to the Kidde control panel. This module is designed for Class B circuit operation.

- The device address is set using the two rotary switches located on the front of the module. Two consecutive addresses are required. The second address is automatically assigned one number higher than the value set on the rotary switches.

- The FX-IDC2B can be preset for alarm or supervisory operation using the slide switch located on the front of the module. It can also be configured for other device types through front panel programming or the configuration utility.

Dual Input Module FX-IDC2B

Communication line voltage Maximum 20 V peak-to-peak
Current

Standby

Activated

550 μA

725 μA

Ground fault impedance 10 k ohm
Operating environment

Temperature

Humidity

32 to 120°F (0 to 49°C)

0 to 93% RH, noncondensing at 90°F (32°C)

Storage temperature range –4 to 140°F (–20 to 60°C)
Compatible electrical boxes

North American 4 inch square x 2-1/2 in. (64 mm) deep 2 gang box

Standard 4 in. square box 1-1/2 in. (38 mm) deep

Wire size 12, 14, 16, or 18 AWG wire (2.5, 1.5, 1.0, or 0.75 sq. mm) (Sizes 16 and 18 AWG are preferred)
Device address

01 to 63 (64 point control panel)

01 to 126 (1000 point control panel)

Initiating device circuit (IDC)

EOL resistor value

Max. circuit resistance

Max. circuit capacitance

47 kΩ, (P/N: EOL-47)

50 Ω (25 Ω per wire)

0.1 μF

Ordering Information

Model Description Ship Weight
FX-IDC1A Analog Class A Single Input Module 0.50 lbs. (0.23 kg.)
FX-IDC1B Analog Single Input Mini Module 0.34 lbs. (0.15 kg.)
FX-2WIRE Analog Class A-B Two-Wire Module 0.50 lbs. (0.23 kg.)
FX-IDC2B Analog Dual Input Module 0.50 lbs. (0.23 kg.)
FX-2IDCWS Analog Dual Input Waterflow-Supervisory Module
FX-NAC Analog NAC Module
FX-RLY Analog Contact Relay Module
FX-ISO Analog SLC Fault Isolator Module
Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Dual Input Module FX-IDC2B

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.15949 sec| 4344.438 kb