Smoke Detectors with Auxiliary Functions 500 Series

Product code : 500 Series

500 Series ⭐
✅ two-wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features that meet the demands of every type of application. The 500 offers sounders in two-wire applications, specifically to meet residential code requirements.

Consulting hotline: 0944934114
Product information

- Kidde is also proud to offer proven technology like CleanMe®, dust compensation, field replaceable optical chambers, and selfdiagnostics. CleanMe® is only available on the 500 2-wire models and will communicate with compatible FACPs when servicing is required.

- 500 Series detectors work on a light-scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a highspeed photo diode as the sensing element. This design has superior protection against nuisance alarms caused by dust, insects, RF interference, and ambient light.

- The proprietary optical chamber is field replaceable. In the event of a confirmed alarm the LED will light continuously. The unit indicates trouble by flashing the LED every second. This meets the NFPA 72 field sensitivity testing requirements.

- Additional diagnostic information is activated by applying a magnet near the detector’s integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The magnet test causes the LED to blink. The number of blink counts corresponds to a smoke detector sensitivity range.

- Models with a built-in 85dB sounders emit the temporal 3 pattern and can be easily tandemly interconnected using the 405-05 polarity reversal relay. This enables all detectors to sound when the initiating detector sounds and meets the requirement of the International Residential Building Code (IRC).

Standard Features

• Remote maintenance (CleanMe®) reporting and builtin drift compensation reduces false alarms

• Self-diagnostics meets NFPA 72 sensitivity testing requirements without the need for external meters

• Field-replaceable optical chamber makes service fast and simple

• Large SEMS screw terminals accept 12-18 AWG wire

• Small, low profile design blends with any environment

• Optional auxiliary functions include:

• Integral sounder with optional tandem interconnection

• Auxiliary relay Listed for applications such as elevator recall

• Fire system isolated heat integrated with nonlatching single station smoke alarm

• Integral fixed/ROR heat detectors

• Adaptor plate enables replacing 500 Series with legacy 400 Series smoke detectors

Application

500 Series detectors are ideal for both retrofit applications and new installations alike. They are particularly well-suited for installations where detector reliability is essential, but where typical analog/addressable devices may not be appropriate or feasible. With their replaceable optical chambers, these detectors are equally well-suited to dusty environments where detectors require frequent cleaning.

Assembly

Dimensions

Typical Wiring

Specifications

Electrical

Power Supply 8.5-33VDC (12/24 V operation) polarity sensitive
Maximum ripple pk-pk (6/12/24V) 10% (Vpk-pk)
Typical average standby current 70 μA
Typical alarm current (6/12/24V) up to 60 mA max if not limited by control panel
Auxiliary relay contacts (521NCRXT only 1.0 A @ 30 VDC; Form C
Photoelectric sensitivity 3.1% + 0.5 - 1.0%

Environment

Operating temperature 32° to 100° F (0° to 37° C)
Operating humidity range 0 to 95% non-condensing
RFI immunity 20 V/m min; 0-1000 MHz

Physical

Color White
Field wiring size 12-18 AWG (16-22 recommended)
Heat detector specifications Rate-of-Rise: 15° F/min and >105° F (8.3° C/min and >40.6° C) Fixed Threshold: 135° F (57.2° C)
UL 2-wire compatibility identifiers S09A, S10A, S11A
Sounder output (521NCSXT only) 85dB @ 10 feet
Drift compensation adjustment 1.0% ft. max
Detector head dimensions 5.5 D x 2" H (14.0 x 5 cm)
Mounting dimensions 5.25" (13.3 cm) diam

Regulations

Reset time 1 second min
Listings

500N Series:

521B, 521BXT:

UL 268 cUL, CSFM

UL 268, CSFM

Ordering Information

Model Description Compatibility Alarm Current (mA) Reverse polarity (mA)
521B 2-wire, photoelectric, 8.5-33VDC; UL 268, CSFM Listed S09A/S10A 5 min. - 60 max.  
521BXT 2-wire, photoelectric, 8.5-33VDC, fixed temp and rate-of-rise heat; UL 268, CSFM Listed S09A/S10A 5 min. - 60 max.  
521NCRXT 2-wire, photoelectric, 8.5-33VDC, fixed temp and rate-of-rise heat, aux. relay; UL 268, cUL, CSFM Listed S11A 15 min. - 60 max.  
521NCSXT 2-wire, photoelectric, 8.5-33VDC, fixed temp and rate-of-rise heat, temporal 3 sounder; UL 268, cUL, CSFM Listed S10A 10 min. - 60 max 10
Note: Only 500 Series 2-wire smoke detectors are CleanMe compatible

Accessories

405-05 Polarity reversal module enables sounder interconnection of all 4-wire smoke detectors, when initiating detector sounds all smokes sound
SM200-12PKG Smoke! in a Can® canned smoke for functional testing
SM-EXT1 Smoke! in a Can® extension tube
211-10PKG Replacement optical chambers (set of 10)

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comments, reviews about Smoke Detectors with Auxiliary Functions 500 Series
Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Bình luận sản phẩm
Write a comment
Product portfolio
0.13521 sec| 4032.047 kb