Notifier NCM fire alarm network control module
Top 5 reviews - 1000 comments Fire Alarm Software Notifier Including models: NCM-W, NCM-F, NCM-SMOF ,Supplying all kinds of fire alarm modules, fire alarm control modules, hochiki addressable fire alarm modules ,dcp-r2ml pdf, hochiki fire alarm, 12 month warranty, unlimited quantity
Network control module
The Network Communication Module (NCM) provides the NOTIFIER AFP-2800 Fire Alarm Control Panel with the means to connect to NOTI • FIRE • NET™. There are three types of NCM: NCM-W for connecting nodes using twisted pair cable and NCM-F for connecting nodes using multimode fiber and NCM-SMOF for connecting single mode fiber.
Feature:
- Wire
- Support medium twisted pair wire.
- Two programmable data thresholds - baud rate 312.5 Kbaud.
- Data is regenerated at each node.
- Two network ports to allow simultaneous connection to the fire alarm control panel and to the programming computer.
- Up to 1000m between nodes in a point-to-point fashion (actual distance varies with wire quality) Nature
- Support multi-mode fiber optic cable.
- The data is immune to any environmental noise.
- Fiber type: 62.5 / 125 micrometers (multimode); or 50/125 micrometers (multi-mode).
- Connection: ST® . type - baud rate 312.5 Kbaud.
-Data is regenerated at each node.
Features of NCM-W
• Support twisted pair wire environment
• Two programmable data thresholds
• Transformer coupling provides electrical isolation between nodes
• Pluggable terminal wiring with strain relief
• Pluggable service connector (signal through direct) in the event that power must be disconnected a node.
• baud rate 312.5 Kbaud
• Data is regenerated at each node
• Two network ports allow simultaneous connection to the fire alarm control panel and to the programming computer.
• Allows upload/download of software and databases via NOTI
• FIRE
• NET™.
• Repeater available to boost signal
• Repeater can be used to switch media type
• Up to 1000m between nodes in a point-to-point fashion (actual distance varies with wire quality) Features of NCM-F
• Multi-mode fiber optic support
• The data is immune to all environmental noises
• Optical isolation prevents ground loops
• NOTI
• FIRE
• NET™ fiber environment
• Fiber type: 62.5 / 125 micrometers (multi-mode); or 50/125 micrometers (multimode)
• Maximum attenuation is 8 dB with 62.5/125 μm cable and 4.2dB with 50/125 μm cable.
• Wavelength: 820 nanometers (using standard 850nm fiber)
• Connector: ST® . type
• baud rate 312.5 Kbaud
• Data is regenerated at each node
• Two network ports allow simultaneous connection to the fire alarm control panel and to the programming computer.
• Allows upload/download of software and databases via NOTI
• FIRE
• NET™. Product line information
- NCM-W: Network communication module, twisted pair wire interface.
- NCM-F: Network CommunicationsModule, multimode fiber optic interface.
- NCM-SMOF: Network Communications Module, single-mode fiber interface
You can refer to products genuine fire alarm equipment...HERE