Carbon Monoxide Detector with SafeTes 260-CO
The 260-CO carbon monoxide (CO) detector⭐
✅ is an accurate and reliable means of alerting building occupants of potentially dangerous levels of CO in the protected area. The internal electro-chemical sensor communicates with a sophisticated on-board microprocessor that accurately tracks CO levels over time
- This commercial-grade detection technology results in quick response, reliable sensing, fast reset time, and superior false alarm immunity. Its small size allows the 260-CO to blend inconspicuously with any decor, and its smooth contoured design is compatible with both residential and commercial environments.
- Unaffected by normal indoor temperature variations, the 260-CO automatically adjusts for environmental changes and operates reliably under a wide variety of conditions. It also monitors its own performance and compensates for sensitivity drift throughout the course of its service life
- The 260-CO features the SafeTest™ functional test feature, which facilitates testing with real CO gas. SafeTest meets the functional test requirement in NFPA 720, 2009/2012 editions
- Like all CO detectors, the 260-CO has a limited service life. But unlike most, which last only six years, the 260-CO’s advanced sensor features a service life rated at 10 years. When it approaches this point, the 260-CO’s end-of-life timer automatically triggers a warning that indicates the device must be serviced. This warning annunciates at the detector, as well as at the control panel, and optionally at a remote monitoring station
- An integrated temporal-4 sounder provides local signaling capability for the 260-CO, and it easily interfaces with any intrusion or fire alarm system by means of its output relay. Its low current draw results in little additional demand on the system power supply.
Standard Features
• 10-year end-of-life signal
• SafeTest™ feature — functional test with spray of real CO gas
• Advanced electro-chemical sensing technology
• Wiring option activates sounders of all connected detectors when any one of them goes alarm
• Deep housing with plenty of room for wiring
• UL 2075 compliant
• Transmits sensor end-of-life to the supervising panel and central station if the system is monitored
• CO sensitivity conforms to UL 2034 requirements
• Built-in trouble/power supervision relay
• Self-diagnostics keep the device operating optimally throughout its service life
• 12 or 24VDC operation and 150mA Form C relay
• Large SEMS terminals ease wiring installation 14 to 22 AWG
• One-touch TEST/HUSH button simplifies local operation
• Integrated 85 dBa temporal-4 sounder for local notification
• On-board LED provides local alarm and trouble indication
• Inconspicuous footprint and attractively contoured design
• Adapter plate simplifies replacing 240-COe detectors
Application
- The 260-CO Carbon Monoxide Detector is intended for ordinary indoor-dwelling unit applications in both residential and commercial occupancies, including single/multiple family residential occupancies, hotel rooms, dorm rooms, and other areas approved by the authority having jurisdiction (AHJ). The 260-CO detector can connect to either UL 985 (Household Fire Warning) or UL 864 (Commercial Fire) control panels. It is not intended for use in industrial applications such as gasoline refineries or parking garages, which require different listings
- The 260-CO is a four-wire device that uses a Class 2 output a control panel. Nonetheless, the primary alarm notification device remains the 260-CO’s internal sounder with the control panel secondary to these purposes. The 260-CO is not a substitute for life safety devices, and should be only considered as an integral part of a comprehensive safety program
- Selecting a suitable location is critical to the correct operation of CO detectors. Install the 260-CO in accordance with NFPA 720 Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment. Place wall-mounted detectors at least 5 ft. (1.5 m) up the floor. For ceiling mounted applications, place the detector at least 1 ft. (0.3 m) any wall
Recommended CO detector locations:
Within 10 ft. (3 m) of all sleeping areas, including areas such as hotel rooms and dorm rooms.
In a suitable environment: areas with a temperature range of 40 to 100 °F (4.4 to 37.8 °C) and with a relative humidity range of 10 to 90% noncondensing.
In residential dwellings, locate detectors in every bedroom and on each level. At a minimum, place one detector outside the sleeping areas
Centrally located on every habitable level of the building and in every HVAC zone based on an engineering evaluation considering potential sources and migration of carbon monoxide
On the ceiling in the same room as permanently installed fuelburning appliances
In any area required by local building codes, legislation, or the authority having jurisdiction
On a firm, permanent surface
Wiring
Specifications
Input voltage | 12 or 24 VDC supplied by UL 985 or UL 864 listed control panel or resettable auxiliary power supply |
Alarm relay Type UL rating |
150 mA at 33 VDC Form C Zone |
Common trouble relay Type UL rating |
150 mA at 33 VDC Normally opened held closed with power applied Common |
Sensor life | 10 years date of manufacture |
Sounder | 85 dB |
Compatible control panel | Listed to UL 985 or 864 standards |
Compatible electrical box | 2-1/2 in. (64 mm) single-gang |
Wire size | 14 to 22 AWG (0.25 to 2.0 mm²) |
Dimensions (W × L × D) | |
Detector Adapter plate |
3.1 × 4.6 × 1.4 in. (7.8 × 11.7 × 3.6 cm) 4.5 × 6.5 × 0.2 in. (11.4 × 16.5 × 0.5 cm) |
Color | White |
Operating environment | |
Temperature Relative humidity |
40 to 100 °F (4.4 to 37.8 °C) 10 to 90% noncondensing |
CO sensitivity |
70 ppm, 60 to 240 minutes 150 ppm, 10 to 50 minutes 400 ppm, 4 to 15 minutes |
Ordering Information
260-CO | Carbon monoxide detector, alarm & trouble relays, sounder, end-of life signal, 12/24VDC |
250-COPLT-5PKG | Adaptor plate for use when replacing the 240-COe CO detector with a 260-CO |
ESL 405-01 | Polarity Reversal Module, 24 VDC |
CO Gas Test Spray | Functional CO gas test spray Solo C-6 SDI (www.sdifire.com) available through security distribution. |
Have 0 comment, evaluate about Carbon Monoxide Detector with SafeTes 260-CO
TVAdministratorsAdministrators