Viking AFFF 1%S C6 is an aqueous film forming concen-trate foam (AFFF) consisting of fluorocarbon and hydrocarbon surfactants mixed with other solvents, preservatives and stabilizers. together. The foam forms a film of water that quickly cuts off the oxygen supply and defeats the flame. The expanded foam, which the film is released, forms a stable blanket, superpresses the flammable vapor and cools the fuel surface, extinguishing the fire and preventing the surface domination of the foam solution. allows the membrane aqueous solution, although heavier than the flammable vapor, to float on the surface of the liquid. Viking AFFF 1%S C6 Foam Solution should be used with 1% by volume (1 part concentrate in 99 parts water) in brackish, freshwater or marine waters. It can also be stored as a premixed solution in fresh water.

Features: Viking AFFF 1%S C6 . Fire Extinguishing Foam

• Tested, listed and approved with Sprinklers

• Excellent fire suppression on Class A and Class B hydrocarbon fires.

• For use in all high-risk applications such as warehouses, hangars, offshore installations, oil and chemical tan-kers, petrochemical and chemical plants.

Standard of Viking AFFF 1%S C6 . Fire Fighting Foam

- FM ApprovedRefer according to approval instructions FM for systems and equipment approved for use with this concentration. Consult equipment and system data sheets Viking, NFPA 11, FM Global Asset Loss Prevention Data Sheet and relevant local standards to design the correct system. FM approval of a foam fire suppression system is subject to design, installation, testing and maintenance performed in accordance with NFPA's Global Property Loss Prevention Data Sheet 11 and/or FM 4-12, System saliva/water spray system

- List of UL

GFGV.EX27255Underwriters Laboratories, 7th Edition of UL 162 Refer to the UL List for systems and equipment approved for use with this concentration. Consult equipment and system data sheets Viking, NFPA 11 and relevant local standards for correct system design.

Specifications of Viking AFFF 1%S C6 . Fire Fighting Foam Solution

Appearance ...................................................................Clear to yellowish liquid

Specific gravity at 68 °F (20 °C) ..............................................1,05 +/- 0.01 g/ml

Viscosity at 77 °F (25 °C) spindle #2, 60 rpm .............................15 mPas +/- 5

Viscosity at 68 °F (20 °C) spindle #2, 60 rpm .............................20 mPas +/- 5

Viscosity at 0 °F (-18 °C) spindle #2, 60 rpm ..........................220 mPas +/- 10

pH .........................................................................................................7,3 to 8,3

Freezing point ............................................................................-36.4 °F (-38 °C)

Recommended storage temperature ...............-36.4 °F to 131 °F (-38 to 55 °C)

UL/FM temperature range ...........................................0 to 120 °F (-18 to 49°C)

Suspended sediment (v/v) ..........................................................Less than 0,2%

Surface tension ..........................................................................≤ 18,0 dynes/cm

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Viking AFFF 1 percent S C6 Foam Solution, Latest Fire Foam Price

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13965 sec| 4333.008 kb