Rapidrop Sprinkler Head RD043, Tyco Ty325 Sprinkler

Manufacture: Rapidrop
Product code: RS043

Rapidrop RD043 Sprinkler Head Quick Response, K=115 (8.0), Temperature 141ºC (286ºF), UK Made ⭐
✅ Quality ⭐
✅ Guaranteed Genuine ⭐
✅ Unlimited Quantity ⭐
✅ Contact Contact now 0917911114 for free consultation 24/7

Zalo

Consulting hotline: 0944934114
Product information

Description of Rapidrop Sprinkler RD043

>>>>>>>>thông tin đầu phun tyco Ty325...Tại đây!!<<<<<

Rapidrop Sprinkler RD043 sprinkler automatic quick response automatic bulb. They are CE Marked, LPCB, VdS, FM approved, UL listed, standard hole fire sprinklers for installation in fire sprinkler systems. The Rapidrop Sprinkler RD043 creates a hemispherical water distribution pattern below the deflector. In fire conditions, the heat causes the liquid in the bulb to expand, shattering the glass and releasing the spring assembly. Water flowing the hole the nozzle deflects the water diffusion a uniform spray pattern to extinguish or control the fire.

Đầu Phun Sprinkler Rapidrop RD043, Đầu Phun Tyco Ty325

Specifications of Rapidrop Sprinkler Head RD043

+ Factor K 115 (8.0)

+ Standard size 20mm ()

+ Standard thread size NPT

+ Feedback Quick response

+ 3mm . bulb Maximum working pressure 12.1 bar (175 psi)

+ Brass finish, chrome and white paint finish. Special RAL colors available upon request

+ Approved FM Approved, UL Listed, LPCB, VdS, CE, Gost Weight: 79 g (2.8 oz)

 

angryangryangryangryangry Tổng hợp các mẫu đầu Phun Tyco UK>>>

Đầu Phun Sprinkler Rapidrop RD043, Đầu Phun Tyco Ty325

 

Nhiệt độ làm việc Đầu Phun Sprinkler Rapidrop RD043

Đầu Phun Sprinkler Rapidrop RD043, Đầu Phun Tyco Ty325

Design coverage of Rapidrop Sprinkler Head RD043

Đầu Phun Sprinkler Rapidrop RD043, Đầu Phun Tyco Ty325

Spray Prink Sprinkler RD043 for standalone installation only produces hemispheric discharge below the deflector with little or no water discharge upwards. For sprinkler coverage area and location, refer to standards NFPA 13 or EN 12845 or other installation rules for automatic sprinkler systems as required by the competent authority. The following details are provided for information only.

 

>>>>Mời quý vị tham khảo thêm một vài mầu đầu phun Sprinkler Rapidrop...Tại đây!!!

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..