Description of Nittan NFU 700 Fire Alarm Control Panel
The Nittan NFU 700 SPERA Fire Alarm Control Panel offers modular components to meet a wide variety of applications. Designed for peer-to-peer network communication, the NFU-7000 enables up to 63 nodes, while providing reliability, flexibility, and scalability. The NFU-7000 EV protocol is based on a platform that has proven its reliability in the European global marine and marine markets.
This Nittan NFU 700 Fire Alarm Panel is supplied with a loop driver card capable of supporting 2 addressable loops, up to 254 addresses per loop and expandable up to 6 ring. Thanks to the contribution of networking capabilities and the range of detectors and addressable modules, the Control Panel is suitable for all site applications small multi-site systems to large complex.
- Ability to control fire alarm
- A 2-loop capable driver card fitted as standard
- NFU-7000 capable of storing three driver cards (up to 6 loops)
- A loop supporting 254 addresses can be wired in class A (style 6 or 7) or class B (style 4
) - No need to use shielded cable for SLC loops
- Modular design
- Four A/B (Z/Y style) announcement device circuits rated at 1.7 Amps each
- One auxiliary supply, rated at 1.7 Amps for 24 VDC, and one resettable 4-wire supply
- Large 16-line x 40-character backlit LCD display with user-friendly menus
- Programmable switch input enables multi-function output
- Four status queues with selector switches and LEDs for alarm, monitoring, troubleshooting and monitoring
- Auxiliary contacts for general alarm, general monitoring and Common trouble
- RS-232 port for remote system printer
- Two Event History Logs including 1000 alarm history logs for alarm related events and 6000 event history logs for all events
- Supports three configuration files (current, previous and next configuration) with hot swap support
- Supports the usual Hardwire add-on modules
- Built-in One Man Walk test activity
- Provides drift compensation for photoelectric smoke detectors
- Ability to adjust the sensitivity of the smart smoke detector
- Real-time 3D graphics monitoring and control of Nittan NFU-Graphics-Monitor
- BACnet support
- Supports Boolean logic functions
- Built-in Ethernet port
- UL listed for smoke control
- Manual control function
- Input simulation function
- Multiple group bypass functions with built-in false alarm prevention technology
- Bypass network button
- Ignore button output
- Skip input area
- Disconnect
- Devices / Loops Features of Nittan NFU 700 Fire Alarm Center Cabinet
- Up to 63 panels
- Peer-to-peer network communication
- Mutual monitoring / 2-way control available
- Class A (Style 6 or 7) or Class B (Style 4) wiring configuration
- ARCNET protocol
- Supports copper and/or fiber cables
Have 0 comment, evaluate about Nittan Fire Alarm Center Cabinet NFU 700