Specifications of MCS UL/FM . Electric Fire Pump Control Cabinet
Model : MCS
Controller: Electric Fire Pump
Power (Horsepower): Soft Start
Voltage: 41 = 415v, 50 hz
Weight: 218 kg - 307 kg
Origin: USA
Warranty: 12 months
Standard: UL/FM
Features MCS UL/FM . Fire Pump Control Cabinet
1. Special features of HMI
● Simultaneous display of 3 phase voltage and current,System pressure, Start/Reset, Manual/Auto and Weekly/Monthly test
●Starting sequence is displayed
● Installation Help
● Summary screen settings
● Start setting with 10 PSI auto increment to Reset settings
● Automatic weekly or monthly check
● Test probes during weekly or monthly testing
● Remote alarm contact test
● Annual Check Reminder
●Service contact information is displayed
● Silent alarm with automatic sound
● Instant conversion PSI to BAR for set pressure
● Multiple password levels
2.Special features of the controller
● 3.5 inch color touch screen display HMI
● The data logger tracks 48 digital and 11 analog signals and exports a CSV file to a USB adapter
● External waterproof USB adapter
● PhaseSmart single phase protection according to NFPA 20
●3 Seconds Reboot Time
● No HMI required for operation control
●No water connection inside the enclosure
● Protective frame for external probe
●Y filter for solenoid valve test protection
● Ambient 50 C mouse temperature
3. Standard Features Starting sequence
● Remote start / Deluge - normally closed Auto Stop
●Automatically check solenoid valve
● Manual pressure drop test button
● Highland delayed start
●Manual, non-automatic operation
● Lock when authorized by AHJ
● 22mm mechanical start/stop button
● Motherboard in steel chassis with latch connector
● DC breaker circuit breaker
● Mechanical and electrical interlock on MCO, MCY and MCT
● Isolation switch and circuit breaker are mounted vertically for safe separation
4. Visual and audible alarm
• AC error
• Low AC voltage
• CB Trip (requires SP1 or SP2)
• Lockout
• Low discharge pressure
• Low suction pressure(83LT)
• Low Zone Start (Demand Enabled)
• Motor overload
• Overvoltage
• Revert phase
• Pump running
• Single phase running
• Probe error
5. On the switch controller
• Normal position
• Normal power supply
• Emergency location
• Emergency Power Available
• Emergency opening CB
6. Remote voltage control
• Running pump (2 sets)
• AC error
• Revert phase
• System problems
• Low start (On request)
7. On the switch controller
• Normal position
• Emergency location
• Emergency opening CB
• Start the generator
Please refer to similar products...HERE
Have 0 comment, evaluate about MCS UL FM Fire Pump Control Cabinet
TVAdministratorsAdministrators