Descriptions Fire alarm control panel CM-P3
Comprehensive monitoring and corresponding indicators: each circuit is equipped with monitoring functions for fire, circuit break and short circuit, respectively
- Fire alarm and indicator circuit can detect circuit break and protect against short circuit
- The system always closely monitors the battery charge and backup battery voltage to ensure that the central control unit works well in all cases to prevent any disaster
- Each circuit is equipped with a test button to ensure the normal function of each monitoring circuit
- Lock-controlled function switches prevent false alarms due to accidental touch
- Voltage fault digital detection: whenever the system detects a voltage fault, a fault alarm will sound and the indicator light will be on The system is equipped with a two-stage accumulator function to prevent false alarms. When the detector activates for the first time, the system will automatically reset the detector. If another signal is received then, the system will confirm that there is a fire, for fear of false alarm
- Self defense mode
- Separate control switches: separate control panels for master, local, indicator and report outputs
- There is an indicator not set above each switch
- Digital electronic switch is used due to the advantage of dustproof and long service life
- One control panel with all the key indicators needed: system alarm status, power quality and circuit connections displayed
- Loud alarm bells: staff in charge will be notified immediately in the event of a certain alarm
- Loud fire alarm: in case of fire, the fire alarm will sound and the large fire alarm will flash
Specifications fire alarm control panel CM-P3
Model | CM-P3 |
Power | 240V AC 50/60 Hz ± 10% |
Pin standard | Pin 24 V DC / Axit chì (Không tràn) |
EOL | 10 KΩ |
EXTERNAL CIRCUIT | To-and -fro dưới 50 |
NO. OF BELLS | 1 mạch bảng |
Charging voltage | DC 26V under 450mA, trickle charge |
Use voltage | Operating voltage 24V DC, less than 5V 32mA |
Charging current | DC 26.4V, less than 450mA, trickle charge |
DETECTORS | No fixed ROR or Temp limit. Heat detector can be installed; Each circuit can connect up to 20 smoke detectors (probe standby current: 24V DC 25 belowA). |
NO. OF INDICATORS | 1 times circuit board |
Structure | Standard material 1.2mm |
REPORT CONTACT | No voltage NO contact Capacity 250V AC 7A × 2 sets |
Infomations oder fire alarm control panel CM-P3
CM-P3-1L | FACP 01 battery area |
CM-P3-2L | FACP 02 battery area |
CM-P3-4L | FACP 04 battery area |
CM-P3-8L | FACP 08 battery area |
CM-P3-12L | FACP 12 battery area |
CM-P3-16L | FACP 16 battery area |
CM-P3-24L | FACP 18 battery area |
Size
Type | WALL-FISHING TYPE | ||
CIRCUIT | 1L / 2L / 4L / 8L | 12L / 16L | 24L |
H (MM) | 400 | 495 | 580 |
W (MM) | 300 | 300 | 300 |
D (MM) | 120 | 120 | 120 |