Fire alarm control panel 2 Loop SIEMENS, FC-1862, FC1861-A2

Manufacture: SIEMENS
Product code: FC-1862/FC1861-A2

FC1862 controller with 2-line card, max.
⭐  504-point FC1862 controller with 4-line card, max., 1008-point FC1863 controller with 6-line card, max. 1512 points FC1861 controller with 2-line card, max. FC1862 504 point controller with 4 line card, max. FC1863 1008 point controller with 6-line card, max. 1512 points

Zalo

Consulting hotline: 0944934114
Product information

- FC1862 controller with 4-line card, max. 1008 points.

- Completing Chinese standards GB4717-2005 and GB16806-2006.

- Multi-language operation menu with window style, easy and fast operation.

- Shortcut key (right key) to pop out device/event activity items.

- Large memory capacity for up to 10000 history records, in first order all events can be recorded during the operation period.

- LCD backlight auto-off mode. When no operations or events are displayed for the preset time, the LCD backlight turns off automatically. When there are events/activity, LCD will automatically light up to show events and/or interlocking devices.

- 2 programmable input/output channels (output: 40mA @ 24VDC, can be programmed as common alarm output or common fault output; input: dry contact). - 1 NAC channel for audible and visible devices (0.5A@24VDC).

- 8 interlocking function channels (output: 40mA @ 24VDC) for automatic control and manual operation of control devices.

- Effective group programming according to different usage.

- FC186x controller can connect up to 2016 points by adding line card.

- Network bus (FC18-BUS), max. distance is 1000m (twist wire capacity is 1.0 to 1.5 mm2). Up to 32 controllers can be networked.

- FRT bus (FR18-Bus), max. distance is 1000m (twist wire capacity is 1.0 to 1.5 mm2). Up to 32 floor repeater displays can be networked.

- Detection bus (FD18-BUS), no 2-wire pole, max. distance for line resistance is 4000m, max. distance for line capacitance is 5000m. (twist wire capacity is 1.0 to 1.5 mm2)

- Three user levels for different active agency. Each user level is accessed with a predefined and changeable password. Convenient plug-in terminals with clear markings for field wiring.

- Auto-mapping function to support operational tasks. The detection algorithm can be adjusted by the controller according to the environment, to provide high alarm reliability and reduce false alarms.

- Programming can be done directly on the controller or through the computer.

- Sticker Sticker Method Easy to operate on site.

Specifications

Tủ Trung tâm báo cháy 2 Loop SIEMENS FC-1862/FC1861-A2

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Fire alarm control panel 2 Loop SIEMENS, FC-1862, FC1861-A2

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.14746 sec| 4321.867 kb