Specifications of Fire Pump Control Panel ECP (UL FM Standard)
Model : ECP
Innovative Fire Pump Controller (EC Series)
Capacity: 40, 50, 60, 75
Voltage: 21 = 208v, 60 hz
Cabinet style: Single door (1 door)
Weight: 123 kg - 180 kg
Origin: USA
Warranty: 12 months
Standard: UL/FM
Features of Fire Pump Control Panel ECP EC Series enhances G4 . performance
• Nema, grade 12, sealed container
• 5.7 inch color touch screen display HMI
• Modbus TCP/IP over Ethernet
• Waterproof adapter for Ethernet connection
• 8 programmable remote alarm relays
• 8 inputs Trouble factory programming
• Consistent coating on all printed circuit boards
• Guaranteed against lightning
Special Features of HMI
• Simultaneous display of 3 voltage and phase current, System Pressure, Start/Reset, Manual/Auto and Weekly/Monthly Test
• The start sequence is displayed
• Installation Assistant
• Settings summary screen
• Start installation with automatic 10 PSI increments to Reset Settings
• Automatic weekly or monthly check
• Test probes during weekly or monthly testing
• Remote alarm contact check
• Annual check reminder
• Service contact information is displayed
• Silent alarm with automatic sound
• Instant conversion PSI to BAR for pressure setting
• Multiple password levels Controller special features
• The data logger tracks 48 digital and 11 analog signals and exports a CSV file to a USB converter
• External waterproof USB adapter
• PhaseSmart single phase protection according to NFPA 20
• Delay restart time by 3 seconds
• No HMI required for controller operation
• No water connection inside the enclosure
• Protective frame for external probe
• Y filter for solenoid protection of test valve
• Rated ambient temperature 50 C Standard Features
• Sequential start
• Remote start / Deluge - normally closed
• Automatic stop
• Automatic check of solenoid valve
• Manual pressure drop test button
• Slow start upland
• Non-automatic operation
• Lock when authorized by AHJ
• 30 mm mechanical start / Push button stop
• Motherboard in steel chassis with latch connector
• Circuit Breaker DC
• Mechanical and electrical interlock on ECO, ECY and ECT . models
• Isolation switch and circuit breaker are mounted vertically for safe separation Visual and audible alarms
• AC error
• Low AC voltage
• CB trip (requires SP1 or SP2)
• Does not start
• Weight
• Lock up
• Low discharge pressure
• Low suction pressure (83LT)
• Low Zone Start (On Demand)
• Motor Overload
• Overvoltage
• Phase reverse
• PhaseSmart
• Alarm of pump factory failure 1 thing 8
• Run the pump
• Single phase running
• Probe error Switch controller on:
• Normal position
• Has normal power
• Emergency location
• Emergency availability
• Emergency opening