Construction of Creative Park Fire Protection Project

Construction of Creative Park Fire Protection Project

 

Thi Công Dự Án PCCC Công Viên Sáng Tạo

Drawing of fire protection system in Park Park

Dong Nam Technology and Technology Trading Joint Stock Company (DONATECH) sincerely thanks the Board of Directors CREATIVE CENTER, Address Ghenh Rang Ward, Quy Nhon City, Binh Dinh Province for your interest, research and use. Use our company's products about

I. Supply of fire alarm equipment, fire fighting equipment (including equipment)

1. Automatic fire detector

2. Fire alarm center

3. Push button, light, fire alarm

4. Link system

5. Power source.

II. Fire sprinkler system installation

- Supply of sprinkler equipment, installation of unburnt systems, fire extinguishers etc

III. Anti-lightning system

IV. Construction time of the project

- Total construction time is 12 months

V. Construction cost

- Total cost of supplying fire alarm equipment, fire fighting equipment, lightning protection equipment, construction and installation of the above items: 2,400,000,000 (Two billion four hundred million VND)

They are currently under construction here

Thi Công Dự Án PCCC Công Viên Sáng Tạo

Creative Park project area, Quy Nhon, Binh Dinh

Thi Công Dự Án PCCC Công Viên Sáng Tạo

N

Member of Dong Nam Company at the Site

All equipment we supply, install and execute are quality tested according to the provisions of fire protection, according to conditional standards.

Basis for the architectural design of the project

+ TCXD 216:1998: Fire prevention - Vocabulary - Fire fighting equipment;

+ TCXD 217:1998: Fire prevention and fighting  - Vocabulary - Specialized terms for fire prevention, rescue and handling of hazardous materials;

+ TCXD 217:1998: Fire detection and alarm system - General regulations;

+ TCVN 3991:1985: Fire prevention standards in construction design - Terms and definitions;

+ TCVN 6379 - 1998: (Fire fighting equipment - Fire hydrant - Technical requirements);

+ TCVN 6102 - 1996: Fire prevention and fighting - Fire extinguishing agent - powder);

+ TCVN 5303: 1990: Fire safety - Terms and definitions;

+ TCVN 3254:1989: Fire safety - General requirements;

+ TCVN 3890:2009, Fire prevention and fighting equipment for buildings and structures – equipment, layout, inspection and maintenance;

+ TCVN 4778:1989: Classification of fires;

+ TCVN 4879:1989: Fire prevention - Safety signs;

+ TCVN 2622:1995: Fire prevention and fighting for houses and works - Design requirements;

+ TCVN 6160:1996:   Fire prevention and fighting of high-rise buildings - Design requirements;

+ TCVN 5040: 1990: Fire prevention and fighting equipment - Graphical symbols on fire prevention diagrams - technical requirements;

+ TCVN 5760:1993: Fire fighting system - General requirements for design, installation and use;

+ TCVN 5738:2001:  Automatic fire alarm system - Technical requirements;

+ TCVN 4513: 1988: Internal water supply - Design standards;

+ TCVN 6305 - 1,2:1997:   Fire protection of automatic sprinkler systems (part 1,2);

+ TCVN 7336:2003: Fire prevention - Automatic sprinkler system;

+ Decree No. 79/2014/ND-CP dated 31/07/2014 of the Government detailing the implementation of a number of articles of the Law on Fire Prevention and Fighting and the Law amending and supplementing a number of articles of the Law on Fire Prevention and Fighting. ;

+ Circular No. 66/2014/TT-BCA dated December 16, 2014 of the Minister of Public Security detailing the implementation of a number of articles of Decree No. 79/2014/ND-CP.

Design and installation requirements

+ TCVN 5687:2010: Air conditioning ventilation  - Design standards;

+ QCXD 06:2010/BXD: National technical regulation on fire safety for houses and works;

+ QCVN 08:2009/BXD: National technical regulation of urban underground works;

+ TCVN 4086: 1985: Electrical safety in construction - General requirements;

+ TCVN 4756: 1989: Rules for grounding and connecting electrical equipment;

+ TCVN 5308: 1991: Technical safety regulations in construction.

In addition, the fire protection system equipment and their installation in the building must also comply with the requirements in the standards cited below:

+ TCVN 4086: 1985: Electrical safety in construction - General requirements;

+ TCVN 4756: 1989: Rules for grounding and zero connection of electrical equipment;

+ TCVN 5308: 1991: Technical safety regulations in construction;

+ TCXDVN 9385: 2012: Lightning protection for construction works - Guidelines for system design, inspection and maintenance.

For any information, please contact us directly: 0917 911 114

You see more : Hồ Sơ năng lực của công ty Chúng tôi

Have 0 comment, evaluate about Construction of Creative Park Fire Protection Project

TVAdministratorsAdministrators

Welcome, honored guests. Please leave a comment, we will respond soon

Reply.
Sender information
Comment
Click here to rate
Sender information

PETROLIMEX JOINT STOCK TANKER COMPANY

PETROLIMEX WATERWAY PETROL AND OIL TRANSPORTATION JOINT STOCK COMPANY is a business unit mainly engaged in coastal and ocean freight transportation.
Detail

VITECH INTERNATIONAL JOINT STOCK COMPANY

CÔNG TY CỔ PHẦN QUỐC TẾ VITECH đã ký hợp đồng kinh tế vào tháng 09/2023 trị giá 2.381.400.000 (2,3 tỷ)
Detail

AIRPOWER JOINT STOCK COMPANY

Contract to supply Ampac fire alarm equipment imported England, with a value of 608,540,800 VND
Detail
Product portfolio
Online support
0.10071 sec| 3621.875 kb