Beam Nittan FIRERAY 50RU 100RU Smoke Detector
Beam Nittan FIRERAY 50RU/100RU Smoke Detector, also known as a beam smoke detector supplied by Nittan Unlimited supply, Genuine warranty commitment, Contact now 0917 911 114 for free consultation 24/7
Detailed Description of Beam Nittan FIRERAY 50RU 100RU Smoke Detector
The system consists of a unit that combines an infrared transmitter and receiver. The signal generated in the transmitter element and reflected by the prism back to the received component is analyzed for the presence of smoke. The internal microprocessor determines the alarm condition when a predefined level is reached. The system is designed to be mounted so the beam will project between 19 vertices (0.5 m) and 24 vertices (0.6 m) below and parallel to the ceiling. Side detection can be up to 30ft. (9,144m) on either side of the beam, providing a maximum total coverage area of 19,800 square feet (60ft. 330ft. or 18.29m x 100m).
Specification of Beam Nittan FIRERAY 50RU 100RU Smoke Detector
The Projection Beam Type Smoke Detector must be a 4-wire 12/24 VDC Device to be used with nationally listed Accredited Testing Laboratory providing 4-wire control panel. Units will be listed to U.L. 268 and will include an integrated transmitter and receiver. The detector will operate between a range of 16.5 ft to 330 ft. (5m to 100m). The beam's temperature range should be -4°F to 131°F (-20°C to +55°C). The beam detector must feature automatic gain control that will compensate for gradual signal degradation the accumulation of dirt on the lens. Unit will include a bracket wall mount. The test will be performed using a flter occlusion test calibration. The smoke detector reflector beam will be either Nittan FIRERAY 50RU (160 ft./50m) or 100RU (330 ft./100m).
Technical Features Beam Nittan FIRERAY 50RU 100RU Smoke Detector
• 2 Models for range: - 50RU: 16.5 ft to 160 ft. (5m to 50m) - 100RU: 160 ft to 330 ft (50m to 100m)
• Easy setup and alignment
• Compact housing
• Includes calibration occlusion check filter
• 3 selectable alarm thresholds: 25%, 35% or 50%
• Microprocessor control
• Latching alarm or auto reset • Automatic control • 12 VDC or 24 VDC . operation • Separate alarm and incident communication
• Remote test station available Performance Features Beam Nittan FIRERAY 50RU/100RU . Smoke Detector
• Latching/non-latching alarm
• Error Status (Trouble)
• occlusion 90% or more (Trouble)
• Automatic control
• Incorrect alignment setting (Trouble)
• Microprocessor control
• 3 sensitivity options
• Indicators - Red LED / Amber LED
Specifications of Beam Nittan FIRERAY 50RU 100RU Smoke Detector