Viking VSH200 Clean Gas Fire Extinguishing System

Manufacture: Viking
Product code: Viking VSH200

Viking VSH200 Clean Gas Fire Extinguisher System is a fire fighting system for server room, gas fire alarm system, gas fire alarm system, hfc fire extinguisher, fire protection system
⭐ Report: System price fire fighting system, Contact us now to find out FM200, Nitrogen, NO2..

Zalo

Consulting hotline: 0944934114
Product information

Detailed description of Viking VSH200 . Clean Gas Fire Extinguishing System

Hệ Thống Chữa Cháy bằng Khí Sạch Viking VSH200, Giá hệ thống chữa cháy

- Guaranteed safe, proven and reliable with no residue and low storage capacity. Viking VSH200 system with HFC-227ea fire extinguishing agent is extremely effective and safe for the environment. The Viking VSH200 Clean Gas Fire Extinguishing System quickly suppresses flammable, electrical and flammable liquid fires before they can cause significant damage and can be used safely where everyone is present. .

- Save floor space in the room with a more flexible design. The VSH200's advanced 725 psi distribution system allows you to position tanks away protected areas, so high-value room floor space is no longer needed for tank storage. This high-pressure system delivers agents in 10 seconds or less much greater distances.

 

Equipment of Viking Clean Gas Fire Extinguishing System VSH200

1. Releasing Devices

Hệ Thống Chữa Cháy bằng Khí Sạch Viking VSH200, Giá hệ thống chữa cháy

- Viking fire suppression systems VSH1230 and VSH200 use an electrical release device to activate each cylinder valve, thereby opening the extinguishing agent container to release the extinguishant to the system.

- In order for the valve to open, the release device must have an electrical signal the fire extinguishing system. In Multi Container Systems, an electric release is used only on the master cylinder and each additional cylinder uses a compressed air release device. The pneumatic release device is threaded the valve and equipped with two connections for the pneumatic pilot(s) (or a pilot and the pilot line safety valve) that are attached via the pilot line adapter.

- Standard: UL/FM

- Specifications

• Maximum operating temperature: UL / ULC 0ºF to 81.5ºF (-18ºC to 27.5ºC), FM 0ºF to 122ºF (-18ºC to 50ºC) Discharge device

• Nominal voltage: 24 V / DC +/- 15%

• Rated current: 0.5 A +/- 10%

• Maximum Monitoring Current: 20 mA

• Punctuality: 100%

2. Clean air tank SVH200

Hệ Thống Chữa Cháy bằng Khí Sạch Viking VSH200, Giá hệ thống chữa cháy

- Standard : UL/FM Specifications

• Minimum and maximum agent storage temperature: 0°F to 122°F (-18°C to 50°C)

• Minimum and maximum protected space temperature per UL and FM: 60°F to 80°F (15.6°C to 26.7°C) Cylinder specifications

• Fill density: Min. 31.2 lb/ft3 (500 kg/m3), Up to 71.1 lb/ft3 (1140 kg/m3) at 69.8°F (21°C)

NOTE: The exact fill amount depends on the amount required extinguishing agent and arrangement of piping.

Specifications

• Working pressure: 360 psi (25 bar) or 725 psi (50 bar) at 70°F (21°C)

• Max. Working pressure: 508 psi (35 bar) or 870 psi (60 bar) at 122°F (50°C)

• Pressure response at Bursting Disc for 360 psi (25 bar) System: 900 psi (62 bar) at 68°F (20°C)

• Bursting Disc return pressure for 725 psi (50 bar)

System: 1276 psi (88 bar) for 2 valves, 1291 psi (89 bar) for 1-1/2 valves at 68°F ( 20°C)

Specifications of the meter

• Agent: HFC-227ea • 360 psi (25 bar) system:

• Maximum pressure: 725 psi (50 bar)

• Indication range: 0 to 508 psi (35 bar)

• 725 psi (50 bar) system:

• Maximum pressure: 1160 psi (80 bar)

• Indicator range: 0 to 870 psi (60 bar)

• Nominal size of gauge: 2 Stones (50 mm)

• Precision class: 1.6

3. Fire extinguishing agent for the system SVH200

Hệ Thống Chữa Cháy bằng Khí Sạch Viking VSH200, Giá hệ thống chữa cháy

- Viking VSH200 fire suppression system uses agent HFC-227ea, which is a zero ozone depleting substitute for Halon 1301 for use as a gaseous extinguishing agent. It is commonly used in Data Processing, Cleanrooms, Museums and Telecommunications Equipment, protecting expensive equipment or content. Agent HFC-227ea is a colorless, odorless, non-toxic flame retardant with zero ozone depletion, low global warming and a short atmospheric lifetime. Extinguishing is due to a combination of chemical and physical mechanisms, causing disruption in fire chemistry

- Standard: UL/FM Specifications

- Minimum and maximum agent storage temperature: 0°F to 122°F (-18°C to 50°C)

- Minimum and maximum temperatures of protected spaces per UL and FM: 60°F to 80°F (15.6°C to 26.7°C)

- Chemical formula: C3HF7 Chemical name: 1,1,1,2,3,3,3-Heptafluoropropane

- Molecular Weight: 170.03ISO Indication: HFC-227ea - Density, Liquid @ 77°F (25°C): 86.53 lb/ft3 (1,386 g/cm3)

- Melting point: -204°F (-131°C) Boiling point: 2.5°F (-16.4°C)

- Viscosity, Liquid @ 77°F (25°C): 0.443 lb/ft/hour (0.184 turtle centipedes)

- Heat of vaporization @ BP: 57.0 BTU/lb (132.6 kJ/kg) Vapor pressure @ 77°F (25°C): 65.7 psi (4.53 bar)

 

4. System nozzles SVH200

Hệ Thống Chữa Cháy bằng Khí Sạch Viking VSH200, Giá hệ thống chữa cháy

- In the VSH200 Fire Extinguishing System, the nozzle is used to apply the extinguishing agent during the calculated flooding time and uniformly distributed in the protected housing. There are two types of nozzles for the VSH200 Fire Extinguishing System:

• 180° nozzle sprays extinguishing agent in a semicircle around the discharge nozzle

• The 360° nozzle sprays the extinguishing agent in a full circle around the nozzle UL/FM . Standard

Specifications

• Minimum and maximum agent storage temperature: 0°F to 122°F (-18°C to 50°C)

• Minimum and maximum temperatures of protected spaces per UL and FM: 60°F to 80°F (15.6°C to 26.7°C)

• Minimum operating pressure: 131 psi (9 bar)

• Maximum operating pressure: 870 psi (60 bar)

• 180° radioactive discharge hose: 36'-8, (11.2 m)

• Drain hose 360° radius: 23'-1 Only (7.1 m)

• Maximum effective nozzle height: 16.4' (5.0 m)

• Maximum quantity of extinguishant per nozzle: 407.8 lbs (725 psi) 338.4 lbs (360 psi)

• Nozzle diameter: Orifice's diameter increment increases by 0.001 inch

• Thread sizes: 1/2, 1, and 1-1/2 NP NP

You can refer to similar products..HERE

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Viking VSH200 Clean Gas Fire Extinguishing System

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13911 sec| 4340.039 kb