SLR-24H Thermal Combined Optical Smoke Detector

Manufacture: INGESCO
Product code: SLR-24H

SLR-24H Thermal Combined Optical Smoke Detector | Hochiki Detailed Description : The combined thermal smoke detector SLR-24H can be used in all areas where optical smoke detectors can be used. The wide sensitivity range makes the SLR-24H detector can be used for many types of fires such as smoldering or burning fires ,12 month warranty , Latest updated price , 24/24 technical consultation 7: 0917911114

Zalo

Consulting hotline: 0944934114
Product information

SLR-24H Thermal Combined Optical Smoke Detector

Application : SLR-24H . Thermal Combined Optical Smoke Detector

The combined thermal smoke detector SLR-24H can be used in all areas where optical smoke detectors can be used. The wide sensitivity range makes the SLR-24H detector can be used for a variety of fires such as smoldering or burning fires. The SLR-24H detector is suitable for base types such as NS-4, NS-6, HSC-4R or HSC-R. Compatible and can completely replace old detectors such as Ion smoke detector SIJ-24, optical smoke detector SLR-24V and semiconductor heat detector DCD-135/190.

Basic Features : SLR-24H . Thermal Combined Optical Smoke Detector

The detector has a total height of only 2.2” Fits 2-wire, 4-wire, relay base types Fixed temperature 135oF The temperature sensor head is protected inside the detector housing. Works with high stability, anti-counterfeiting infrared transceiver technology Low Standby Current – 45uA at 24VDC Built-in 2 LEDs for power status/sensitivity monitoring/fire alarm Omnidirectional smoke chamber Anti-disassembly, anti-disassembly function. The smoke chamber is removable for cleaning or replacement Automatic jump in compliance with NFPA 72

Specification : SLR-24H . Thermal Combined Optical Smoke Detector

Light emitting source: GaAlAs . infrared LED Operating voltage: 12 VDC or 24VDC Alarm temperature for heat alarm: 135oF (For SLR-835H) Alarm current: 150mA Incremental current: 200uA Average current in normal state: 38uA @12VDC and 55uA @24VDC and 70uA @35VDC Operating Temperature: 32oF – 120oF (0oC – 49oC)

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about SLR-24H Thermal Combined Optical Smoke Detector

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.16015 sec| 4327.477 kb