Naffco UL FM Central Control Cabinet 2 or 4 Loops
Naffco UL/FM Central Control Cabinet (2 or 4 Loops) is the 100% best choice for your fire alarm system Genuine import, Unlimited supply, Guaranteed genuine , Please contact immediately 0917 911 114 for free consultation 24/7
Detailed description of Naffco UL FM Central Control Cabinet 2 or 4 Loops
- The SA-P20R and SA-P4LR analog addressable FACPs support 2 or 4 rounds of SLC for a total of 500 primary points or 800 points using subpoints. SLC ring communication uses standard twisted pair cable, shielded cable is not required.
- Naffco UL/FM Central Control Panel (2 or 4 loops) can be configured with different communication cards; Communication options support central station monitoring, Virtual Console and networking.
- Naffco UL/FM Central Control Panel (2 or 4 loops) can be configured as a stand-alone control panel with only a few devices for a small building, it can also act as a system buildings and can be part of a network with a total of 64 nodes serving multiple campus buildings or very large facilities
- The Auto Learn capability provides a convenient method for troubleshooting a new installation before the final program loads.
Specification Naffco UL FM Central Control Cabinet 2 or 4 Loops
- 9th edition of UL 864
- The address is similar to multiple rings 2
- Loops Field can be upgraded to 4
- 126 key points per loop
- Powerful, network wide cause and effect (500 total). Fully user-programmable by point or zone
- 800 points per board when using a device with extra points
- Cord lengths up to 10,000 ft on SLC . ring
- 64 pounds online
- Programming via PC connection to the console or through the keyboard
- Programmable relay - 5
- Monitored output - 3
- Programmable notification device circuit: 4
- Power per NAC: 1.6 Amps Max
- Programmable output on the SLC . ring
- Programmable function button on front display
- Fire button on the front screen
- Day and night sensitivity settings (user programmable)
- Power supply: 5.25 Amp, regulated and built-in
- LCD screen: 8x40 - Zonal mode: Regional notifications with individual relationships
- Group stage modes: General, Zonal and Stage 2
- Programmable NAC output as Continuous, March, Momentary
- Program Cause and Effect AND, OR or any two (Cross Area)
- Battery size: Up to 17 Ah in standard case; up to 52 Ah with external cabinet
- Access level: 3
- Access key: Yes
- Approved for use in High Boost
- Test - Fire test mode - Red
You will receive a quote from us as soon as possible..