Naffco Conventional Fire Alarm Center Cabinet UL FM

Manufacture: Naffco
Product code: Alarm Center Cabinet UL FM

Naffco Conventional Fire Alarm Center Cabinet (UL/FM)
✅ Unlimited supply , Genuine warranty commitment , Please contact immediately 0917 911 114 for free consultation 24/7

Zalo

Consulting hotline: 0944934114
Product information

Description of Naffco Conventional Fire Alarm Center Cabinet UL FM

Tủ Trung Tâm Báo Cháy Thường Naffco (UL/FM)-Báo Giá Thiết Bị Báo cháy Hochiki

Naffco Conventional Fire Alarm Panels are designed and manufactured to the highest standards in quality controlled environments, and with UL & FM approvals, Shield A-XT release panels provide value and performance outstanding for all small to medium fixed fire installations. With three detection zones as standard, the extinguishing release can be configured to trigger any combination of detection zone inputs to allow (among other combinations) any two of the three to trigger. as would be required to detect in ceiling, room and floor void applications. The Shield A-XT's extensive configuration options allow for extensive modification of system functionality. The control panel contains a large LED display to allow for easy configuration and control, which also displays the time remaining until extinguishing release for added user safety. The countdown timer is replicated across up to seven remote status units to provide a local indication of system status.. With all electronics mounted on a single, easily removable plate, the Shield A-XT steel plate is both robust and easy to install.. The A-XT Shield is offered in an enclosure that matches the design and color scheme of the elite RS range and is available in standard red or optional gray. Naffco Conventional Fire Alarm Panels (UL/FM) include the following models:

Tủ Trung Tâm Báo Cháy Thường Naffco (UL/FM)-Báo Giá Thiết Bị Báo cháy Hochiki

Specifications of Naffco Conventional Fire Alarm Center Cabinet UL FM

Tủ Trung Tâm Báo Cháy Thường Naffco (UL/FM)-Báo Giá Thiết Bị Báo cháy Hochiki

Technical characteristics of Naffco Conventional Fire Alarm Center Cabinet UL FM - UL864 and FM listed

- Three starter circuits are standard - Any single region or any combination of regions can be configured to release

- Configure the first stage NAC delay

- Configurable detection delay

- No lag time when manual release option

- Compatible with I.S. barriers

- Optional latch-free zone input to receive signals other systems, such as suction equipment

- Configurable extinguisher delay up to 60 seconds in 5 steps

- Configurable extinguishing time up to 5 minutes in 5 second steps

- Countdown timer shows time remaining until release

- Supports up to seven, four wire status indicators

- Built-in fan extract control

Tủ Trung Tâm Báo Cháy Thường Naffco (UL/FM)-Báo Giá Thiết Bị Báo cháy Hochiki

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Naffco Conventional Fire Alarm Center Cabinet UL FM

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.15255 sec| 4332.578 kb