LPCB Addressable fire alarm system 32 zone control panel AW-FP300
The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualit..
The fire alarm control panel is an important part of the fire alarm system. It is mainly used to receive, display and transmit fire alarm signals, and has the function of issuing control signals.
The main functions of the fire alarm control panel are system power supplying, fire alarm signal receiving, and equipment linkage.
1.System Power Supplying
The fire alarm control panel can provide a stable power supply for external devices such as smoke detectors. Meanwhile, it can also monitor the working status of external devices and the system itself.
2.Fire Alarm Signal Receiving
The fire alarm control panel can receive, convert, and process the fire alarm signal output the detectors, giving sound and light alarms, indicating the specific location and time of the fire alarm, and recording the alarm information.
3.Equipment Linkage
The fire alarm control panel can activate the fire alarm signal through the fire alarm sending device or activate the automatic fire extinguishing equipment and linkage control equipment through the automatic fire extinguishing control device.
LPCB Addressable fire alarm system 32 zone control panel AW-FP300
Therefore, we can see that the main functions of the fire alarm control panel are to provide a high-stability DC power supply to the fire detectors, to monitor whether the transmission wires connecting the fire detectors are faulty, and to receive the fire alarm signals sent by the fire detectors. It can convert and process the fire alarm signals, giving out sound and light warnings, then activating the fire-fighting equipment.
The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualities of simple installation, operation and easy maintenance.
The AW-FP300 Fire Alarm Control Panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities. It is compatible with other peripherals made by ASENWARE with its own protocol.
Addressable fire alarm system AW-FP300 Features:
The AW-FP300 single loop 32 zone fire alarm control panel offers the following features:
1. Up to 324 addresses on one loop
2. An easy to read, 4.3'' color screen LCD with a resolution of 480×272
3. Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm
4. Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation
5. An independently programmable conventional sounder circuit output
6. Integral power supply and battery
7. Integral printer
8. Flexible and intuitive cause and effect programming on front panel
9. Zone test, point test and module start/stop testing facilitate the commissioning
10. U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance
11. Hierarchy management with three access levels
12. Anti-tamper protection by a key lock
13. CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP
Addressable fire alarm control panel Technical parameters:
Nguồn cấp | ||
Nguồn cung cấp | 230VAC (-15%, + 10%). 47 ~ 63Hz. Dòng điện tối đa 0.8A | |
Cầu chì chính | T3.15AL250V | |
Điện áp hoạt động | 18,5 ~ 30VDC | |
Cáp nguồn được đề xuất | Cáp điện lưới có sàng lọc hoặc tiêu chuẩn / màu đen, kích thước cáp 0,75mm2 | |
Power rating | Imax.a = 1,2A; Imax.b = 2,6A; Imin = 0,65A | |
Tối đa sạc | 1,2A | |
Nguồn tối đa cung cấp pin | 4A (khi Nguồn bị ngắt kết nối) | |
Dung lượng pin, loại và kiểu máy được đề xuất | Tối đa dung lượng 2 × 12V / 17Ah; Min. dung lượng 2 × 12V / 12Ah VRLA. PS-12170 cho 17Ah (Power-sonic), PS12120 cho 12Ah (Power-sonic) |
|
Tối đa nội trở của pin | 1,5Ω | |
Cầu chì pin | F8AL250V | |
Cáp pin được đề xuất | 14AWG | |
Dòng tĩnh (đầy tải) | Dòng tĩnh (đầy tải) | |
Kết quả đầu ra | ||
SC Out (+, -) | Điện áp đầu ra | 30VDC |
Tối đa sản lượng hiện tại | 0,5A | |
Đánh giá cầu chì | F1AL250V | |
Điện trở cuối dòng | 4K7 | |
Loại cáp được đề xuất | Cáp trơn không có vỏ bọc, 1.5mm2 | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
Khoảng cách truyền | ≤1500m | |
Tối đa số lượng âm thanh @ 50mA |
20 |
|
FPE Out (+, -) FA Out (+, -) |
Điện áp đầu ra | 18,5 ~ 30VDC |
Tối đa sản lượng hiện tại | 0,5A | |
Đánh giá cầu chì | F1AL250V | |
Điện trở cuối dòng | 4K7 | |
Loại cáp được đề xuất | Cáp trơn không có vỏ bọc, 1.5mm2 | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
Khoảng cách truyền | ≤1500m | |
Lỗi đầu ra (NC, COM, NO) |
Công suất liên hệ | 30VDC @ 2A, 125VAC@0.5A |
Loại cáp được đề xuất | Cáp trơn không có vỏ bọc, 1.5mm2 | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
24VK (+, -) | điện áp đầu ra | 18,5 ~ 30VDC |
Tối đa sản lượng hiện tại | 0,6A | |
Đánh giá cầu chì | F1AL250V | |
Loại cáp được đề xuất | Cáp trơn không có vỏ bọc, 1.5mm2 | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
Đầu vào | ||
Thay đổi lớp (+, -) | Chế độ đầu vào | Thụ động |
Điện trở cáp | ≤500Ω | |
Loại cáp được đề xuất | Cáp trơn không có vỏ bọc, 1.5mm2 | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
Vòng | ||
Vòng ra (+, -) Vòng vào (+, -) |
Điện áp đầu ra | 16,5 ~ 30VDC, xung |
Sản lượng hiện tại | 0 ~ 0,3A | |
Loại vòng lặp | Loại A | |
Loại cáp được đề xuất | Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1.5mm2 | |
Khoảng cách truyền | ≤1000m | |
Đường kính cáp | 1mm2 ~ 2mm2 | |
Giao tiếp mạng | ||
RS-485 | Tối đa số lượng FIP | 30 |
Tốc độ truyền | 9600 bps | |
Loại cáp được đề xuất | Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1mm2 | |
Khoảng cách truyền | ≤1000m | |
Đường kính cáp | 1mm2 ~ 5mm2 | |
CÓ THỂ | Tối đa | 20 |
Tốc độ truyền | Tùy chọn: 10 nghìn, 20 nghìn, 50 nghìn và 100 nghìn bps | |
Loại cáp được đề xuất | Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1mm2 |