LPCB Addressable fire alarm system 32 zone control panel AW-FP300

Manufacture: INGESCO
Product code: AW-FP300

The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualit..

Zalo

Consulting hotline: 0944934114
Product information

The fire alarm control panel is an important part of the fire alarm system. It is mainly used to receive, display and transmit fire alarm signals, and has the function of issuing control signals.

The main functions of the fire alarm control panel are system power supplying, fire alarm signal receiving, and equipment linkage.

1.System Power Supplying

The fire alarm control panel can provide a stable power supply for external devices such as smoke detectors. Meanwhile, it can also monitor the working status of external devices and the system itself.

2.Fire Alarm Signal Receiving

The fire alarm control panel can receive, convert, and process the fire alarm signal output the detectors, giving sound and light alarms, indicating the specific location and time of the fire alarm, and recording the alarm information.

3.Equipment Linkage

The fire alarm control panel can activate the fire alarm signal through the fire alarm sending device or activate the automatic fire extinguishing equipment and linkage control equipment through the automatic fire extinguishing control device.

LPCB Addressable fire alarm system 32 zone control panel AW-FP300

LPCB Addressable fire alarm system 32 zone control panel AW-FP300

Therefore, we can see that the main functions of the fire alarm control panel are to provide a high-stability DC power supply to the fire detectors, to monitor whether the transmission wires connecting the fire detectors are faulty, and to receive the fire alarm signals sent by the fire detectors. It can convert and process the fire alarm signals, giving out sound and light warnings, then activating the fire-fighting equipment.
The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualities of simple installation, operation and easy maintenance.

The AW-FP300 Fire Alarm Control Panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities. It is compatible with other peripherals made by ASENWARE with its own protocol.

Addressable fire alarm system AW-FP300 Features:

The AW-FP300 single loop 32 zone fire alarm control panel offers the following features: 

1. Up to 324 addresses on one loop

2. An easy to read, 4.3'' color screen LCD with a resolution of 480×272

3. Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm

4. Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation

5. An independently programmable conventional sounder circuit output

6. Integral power supply and battery

7. Integral printer

8. Flexible and intuitive cause and effect programming on front panel

9. Zone test, point test and module start/stop testing facilitate the commissioning

10. U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance

11. Hierarchy management with three access levels 

12. Anti-tamper protection by a key lock

13. CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP

Addressable fire alarm control panel Technical parameters:

 

 Nguồn cấp 
Nguồn cung cấp  230VAC (-15%, + 10%). 47 ~ 63Hz. Dòng điện tối đa 0.8A 
Cầu chì chính  T3.15AL250V 
Điện áp hoạt động  18,5 ~ 30VDC 
Cáp nguồn được đề xuất  Cáp điện lưới có sàng lọc hoặc tiêu chuẩn / màu đen, kích thước cáp 0,75mm2
Power rating  Imax.a = 1,2A; Imax.b = 2,6A; Imin = 0,65A 
Tối đa sạc  1,2A 
Nguồn tối đa cung cấp pin 4A (khi Nguồn bị ngắt kết nối) 
Dung lượng pin, loại và kiểu máy được đề xuất  Tối đa dung lượng 2 × 12V / 17Ah; Min. dung lượng 2 × 12V / 12Ah 
VRLA. PS-12170 cho 17Ah (Power-sonic), PS12120 cho 12Ah (Power-sonic) 
Tối đa nội trở của pin  1,5Ω
Cầu chì pin  F8AL250V 
Cáp pin được đề xuất  14AWG 
Dòng tĩnh (đầy tải)  Dòng tĩnh (đầy tải) 
Kết quả đầu ra 
SC Out (+, -)  Điện áp đầu ra  30VDC 
Tối đa sản lượng hiện tại  0,5A 
Đánh giá cầu chì  F1AL250V 
Điện trở cuối dòng  4K7
Loại cáp được đề xuất  Cáp trơn không có vỏ bọc, 1.5mm2
Đường kính cáp  1mm2 ~ 2mm2
Khoảng cách truyền ≤1500m
Tối đa số lượng âm thanh @ 50mA

20

FPE Out (+, -) 
FA Out (+, -) 
Điện áp đầu ra  18,5 ~ 30VDC 
Tối đa sản lượng hiện tại  0,5A 
Đánh giá cầu chì  F1AL250V 
Điện trở cuối dòng  4K7 
Loại cáp được đề xuất  Cáp trơn không có vỏ bọc, 1.5mm2 
Đường kính cáp 1mm2 ~ 2mm2 
Khoảng cách truyền  ≤1500m 
Lỗi đầu ra 
(NC, COM, NO) 
Công suất liên hệ  30VDC @ 2A, 125VAC@0.5A 
Loại cáp được đề xuất  Cáp trơn không có vỏ bọc, 1.5mm2 
Đường kính cáp  1mm2 ~ 2mm2 
24VK (+, -)  điện áp đầu ra 18,5 ~ 30VDC 
Tối đa sản lượng hiện tại  0,6A 
Đánh giá cầu chì  F1AL250V 
Loại cáp được đề xuất  Cáp trơn không có vỏ bọc, 1.5mm2 
Đường kính cáp  1mm2 ~ 2mm2 
Đầu vào 
Thay đổi lớp (+, -)  Chế độ đầu vào  Thụ động 
Điện trở cáp  ≤500Ω
Loại cáp được đề xuất  Cáp trơn không có vỏ bọc, 1.5mm2 
Đường kính cáp  1mm2 ~ 2mm2 
Vòng 
Vòng ra (+, -) 
Vòng vào (+, -)
Điện áp đầu ra  16,5 ~ 30VDC, xung 
Sản lượng hiện tại  0 ~ 0,3A 
Loại vòng lặp Loại A
Loại cáp được đề xuất  Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1.5mm2 
Khoảng cách truyền  ≤1000m 
Đường kính cáp  1mm2 ~ 2mm2 
Giao tiếp mạng 
RS-485  Tối đa số lượng FIP  30
Tốc độ truyền  9600 bps 
Loại cáp được đề xuất  Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1mm2 
Khoảng cách truyền  ≤1000m 
Đường kính cáp  1mm2 ~ 5mm2 
CÓ THỂ  Tối đa 20
Tốc độ truyền  Tùy chọn: 10 nghìn, 20 nghìn, 50 nghìn và 100 nghìn bps 
Loại cáp được đề xuất  Cặp xoắn có sàng lọc hoặc không có sàng lọc, 1mm2 

Please see also AV lice press equipment HERE

Or all ASENWARE fire alarm equipment 

 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about LPCB Addressable fire alarm system 32 zone control panel AW-FP300

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.13345 sec| 4373.82 kb