Hochiki ALN-V addressable smoke detector

Product code: Hochiki ALN-V

The best place to sell Hochiki ALN-V address smoke detectors today in Ho Chi Minh City
✅ Compare prices 8 stores
✅ Prestigious place to buy
✅ Best warranty
✅ Updated 2019
✅ Contact 0917911114

Zalo

Consulting hotline: 0944934114
Product information

General information about Hochiki ALN-V . Addressable Smoke Detectors Hochiki ALN-V . Addressable Smoke Detector

– Hochiki ALN-V Addressable Smoke Detector Has 2 LEDs to indicate power and alarm status.

– Hochiki ALN-V Addressable Smoke Detector High aesthetics – total height of detector and base is 2”.

– Simple and reliable way to set device address.

– Hochiki ALN-V Addressable Smoke Detector Automatic sensitivity compensation due to dust during use. - Automatic fire alarm check feature.

– Hochiki ALN-V Addressable Smoke Detector Using “Digital Communication Protocol” (DCP) with good anti-interference ability, and optimized interrupt for the fastest signal transmission time in case of fire alarm.

– Hochiki ALN-V Addressable Smoke Detector Can be programmed so that the LED does not blink when in operation, suitable for smoke detectors used in bedrooms.

– Hochiki ALN-V Addressable Smoke Detector Omnidirectional smoke chamber.

– Feature to lock the detector to the base, preventing the unintentional removal of the detector the base.

- Detachable smoke chamber, convenient for cleaning and replacing.

Hochiki ALN-V addressable smoke detectors are suitable for detecting smoke fires of various materials such as furniture, plastic, foam or materials that produce a lot of smoke and can can see. The design of the Hochiki ALN-V Addressable Smoke Detector allows optimal response time to the fire, while also minimizing false alarms. Hochiki Address Detector ALN-V . Wiring Diagram Detailed Specifications of Hochiki ALN-V . Addressable Optical Smoke Detectors

– According to standard: UL/FM

– Voltage: 17-41 VDC

– Working current: 450μA

– Alarm current : 540μA

– Hochiki ALN-V Addressable Smoke Detector Protocol: DCP

– Digital Communication Protocol

– Humidity: 95% RH Non-Condensing Working Temperature: 14°F to 122°F Range (-10°C to 50°C) UL standard working temperature: 32°F to 115°F (0°C to 47°C)

– Sensitivity: 0.7 – 4.0%/FT@300FPM 0.7

– 3.86%/FT@2000FPM 0.7 – 2.65%/FT@4000FPM

– Wind speed Hochiki ALN-V Addressable Optical Smoke Detector : 0-4000 fpm

– Material: Bone / White – ABS Blend

– Weight: 3.4oz (5.1 oz. with 4″ base)

– Use with base: YBN-NSA-4, HSB-NSA-6, ASB, SCI-B4 and SCI-B6.

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Hochiki ALN-V addressable smoke detector

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13756 sec| 4323.219 kb