DUCTSD,Single sensor 4-wire photoelectric low flow smoke detector

Manufacture: System Sensor
Product code: DUCTSD

DUCTSD,Single sensor 4-wire photoelectric low-flow smoke detector is a System Sensor fire alarm device, genuine imported Singapore Fire Alarm, price of fire detector: 0917.911.114

Zalo

Consulting hotline: 0944934114
Product information

Featured

• 4-wire photovoltaic, integrated low-flow technology

• Airspeed rating 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s)

• Flexible mounting options: square or rectangular configuration

• Integrated smoke test port cover

• Plug-in sensor offers the latest in sensing technology

• Wide range for operating temperature (–4°F to 158°F) and humidity (0% to 95% non-condensing)

• Patented sampling tube installs the front or rear of the detector without tools

• Increase wiring space with an additional inch conduit connector

• An easy-to-access Test/Reset button

• Patented interconnect feature to turn off multiple fans

• High-contrast terminal symbols and wiring diagram labels make wiring easy

• Built-in short-circuit protection operator's wiring error

• Two DPDT Form-C . relay contacts

• 24 VAC / DC or 120 VAC

• Compatible with existing System Sennsor chimney products, including remote accessories RTS151 and RTS151KEY

Specifications

Air duct velocity 100 to 4000 ft / minute (0,5 to 20,32 m / second)
DPDT . alarm auxiliary contact 10A @ 30 VDC (resistor); 10A @ 250 VAC (resistor); 1/2 HP @ 240 VAC; 1/4 HP @ 120 VAC
Alarm 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz
Initialize alarm 2.0A @ 30 VDC (resistor)
Alarm response time 15 second
Size rectangular 14,38 in (37 cm) L; 5 in (12,74 cm) W; 2,5 in (6,36 cm) D Square: 7,75 in (19,7 cm) L; 9 inch (22,9 cm) W; 2,5 in (6,36 cm) D
Input capacitance Max 270 μF
Humidity 0% to 95% relative humidity non-condensing
Temperature -4 ° F to 158 ° F (-20 ° C to 70 ° C)
Voltage 20-29 VDC; 24 VAC, 50-60 Hz; 120 VAC 50-60 Hz
Start-up time 35 second. maximum
Reset time (power off) 0,6 second. maximum
Reset time w RTS451 0,03 to 0,3 second
Reset voltage Minimum 3.0 VDC .; Minimum 2.0 VAC; 10 VAC min
Packing weight 2,5 lbs. (1,14 kg)
Standby line 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz
Storage temperatures -22 ° F to 158 ° F (-30 ° C to 70 ° C)
Voltage range 20-29 VDC; 24 VAC 50-60 Hz; 120 VAC 50-60 Hz
Wiring 4- wire
Standard DUCTSD,Đầu báo khói lưu lượng thấp quang điện 4 dây cảm biến đơn

Please see similar products….HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about DUCTSD,Single sensor 4-wire photoelectric low flow smoke detector

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.22463 sec| 4341.758 kb