Detnov CCD-103 3-zone Central Fire Alarm Cabinet
fire alarm center for risk control (including 3 detection zones)
✔️It has 1 output to activate bottle and 1 output to activate sign, 2 inputs to monitor bottle, push button input, trip go, abort and pause shut off, 2 siren outputs for two possible states of the extinguishing process, configurable extinguishing trigger delay, 3 fire block operation modes, Manual public, auto and bypass, 2 inputs for room monitoring: door and ventilation , Historical recording of events. Possibility to connect to a PC via USB for complex programming and download events. Integrate with analog systems directly the analog loop. EN12094/1, CPR EN54-2 and EN54-4 certificates ,Requires 2 BTD-1207 batteries
° 3 conventional and endangered detection zones 1 monitored siren output
° Set chime delay on PCB
° Output to trigger bottle and output to trigger signal 2 inputs to monitor tank, pressure and flow Push button inputs: trip pause, cancel and shut down
° 2 output sirens for two possible states of the extinguishing process
° Configurable trip delay
° Extinguishing block operating modes: manual, automatic and bypass 2 entrances for enclosure monitoring: door and ventilation
° Record history of 500 events
° Multi-language keyboard
° Optional card for loop integration of the CAD-150 analog system by Detnov Configuration software
Specifications
Voltage | 90-264VAC 50/60 Hz |
Battery backup | 2 x 7.5 Ah |
Zone (zone) The maximum current in the warning of the zones: Maximum quiescent current for detector: Maximum number of devices per zone: Maximum resistance zone: |
3 areas and 1 risk 82 mA 3,5 mA 32 detectors / 10 push buttons 44 Ω |
Sirens . output Maximum load: Selectable onboard delay: |
450 mA per output 0 - 10 minutes |
No voltage relay output | 10A to 30VCC |
Auxiliary 24V output | 450 mA |
Sirens output, bottle and shutdown state: Output voltage at rest: Enabled output voltage: Maximum current: |
-5VCC to -9VCC Min. 18VCC Max. 29VCC 450 mA |
Ventilation relay output: Free voltage relay: Maximum conversion capacity: |
1 relay with C, NO, NC . contacts 10A to 30VDC |
Temperature | -5ºC to 40ºC |
Humidity | 95% |
Protection class | IP30 |
Size | 443 mm x 268 mm x 109 mm |
Weight (without battery) | 1,9 kg |
Certificate | EN 54-2, EN 54-4 và EN 12094-1 |
Certification Number | 0370-CPR-1868 |