Dau Bao Khoi address FDKU012-PSA

Manufacture: Nohmi
Product code: FDKU012-PSA

Photoelectric Smoke Detector (FDKU012-PSA) is an analog/addressable smoke detector compatible with any Integlex Multicrest series fire alarm control panel, the FDKU012-PSA is a low profile smoke detector with wide sensitivity range. , Detector and base (not included) are made of a durable plastic that is eggshell white (pale white) to blend in with the ceiling. The FDKU012-PSA has a sensitivity range of 3.4 to 12.0%/m (1.05 to 3.82% per foot) and is UL and cUL listed. The FDKU012-PSA can be configured for drift compensation and also has a built-in dirty detector alarm. The FDKU012-PSA and control panel communicate via a robust and proven digital communication pipeline and device-specific alarm level analysis system. The total polling rate is less than five (5) seconds, as required by UL.

Zalo

Consulting hotline: 0944934114
Product information

Featured

• Low profile, less than 2 inches with base

• Wide dynamic range 3.4 to 12.0%/m 1.05 to 3.82%/foot)

• Analog True . probe

• UL . Listed Smoke Calibration and Sensitivity

• Optional Lock tab to prevent unwanted deletion

• Simple and precise address setting without mechanical switches

• LED light for 360° . viewing

+++ Model no. FDKU012-PSA

The FDKU012-PSA has an air velocity rating in the open guard zone 0 to 91.4 m (300 feet) per minute.

The FDKU012-PSA is UL/ULC listed on a maximum distance limit of 9.1m (30 feet) on smooth ceilings. Refer to NFPA 72 for specific information on detector range, location, and special applications.

Specifications

No Item Specifiactions
1 Operating voltage 22.0 to 24.0V
2 Standby current 250 µA
3 Indicators Alarm 2 LEDs
4 Warning Indicators 1.2 mA D.C.
5 Warning point range 3.4 to 12.0 %/m (1.05 to 3.82 %/foot)
6 Working temperature 0°C to 49°C (32°F to 120°F)
7 Humidity 0% to 93% (no condensation)
8 Start-up time 1 second max.
9 Color WHite
10 Weight 84g (2.96 oz)
11 Dimension Height: 34mm (1.33 inch) Diameter: 99mm (4.0 inches)

Address setting

Each addressable module, smoke detector, heat detector and combined detector must have the address set before connecting the device to the Signal Circuit (SLC) loop. The address is set using the handset programmer or the addressing feature on the control panel.

Please see similar products….HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Dau Bao Khoi address FDKU012-PSA

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.61167 sec| 4335.898 kb