Cut filter lightning equipment PROLINE TSG

Manufacture: Đông Nam

Price of lightning protection device PROLINE TSG, imported genuine, 100% effective in lightning prevention, contact 0917 911 114

Zalo

Consulting hotline: 0944934114
Product information

Cut - filter lightning equipment PROLINE TSG can ensurrance for electronic and telecommunications equipment using single-phase and three-phase power grids. These equipment are installed at input points of power source (continuted conection) provided to equipment, construction. Cut - filter lightning equipment PROLINE TSG with parts cut clay and clay filter cut is made in the form of separate blocks, can replace parts easily, low cost, consistent with the climate of Vietnam.

With a multi-level protection solution, the device is able to both cut and lightning impulses to completely eliminate the overvoltage, over current on the power supply line.

The structure of POSTLINE TSG lightning cutting equipment:

Filter lightning : It is designed with a low pass filter, which is a combination of filter coil and filter capacitor x2 used in large circuits.

Primary lightning: The primary lightning element utilizes TSG technology to suppress large amounts of lightning impulses and over-voltage pulses to ground or neutral lines.

Secondary Lightning: Secondary lightning using TDS technology cuts off the lightning bolt on the power supply line, able to distinguish lightning impulses and over-voltage pulses caused by circuit breakers. Out Capable of self-recovery due to AC short circuit

Working Principle:

Cut - filter lightning equipment PROLINE TSG

- Electric discharge horns ensure the ability to dissipate high intensity clay.

- The stream member is composed of layers that are in layers forming gaps, arcs are broken down and are easily extinguished.

- The trigger system consists of excitation and excitation circuits with the function of activating the main electrical discharge by generating an electrical discharge whenever the over-pulse sensation across the circuit exceeds 500V.

- Electric discharge will develop the main discharge between the two horn launchers.

Specifications:

 

  Cut - filter lightning equipment PROLINE TSG

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Cut filter lightning equipment PROLINE TSG

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13630 sec| 4313.797 kb