Descriptions Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

An innovative advanced delivery clean agent fire suppression system developed to provide fire protection for larger enclosures requiring longer agent flow distances.

With the patented-technology of “piston flow”, the ADS system is capable of delivering greater mass flow rates (2.5 to 3 times faster) than a standard clean agent fire suppression system. This innovation allows networking of longer pipe runs in complex configurations with smaller pipe sizes for protection of larger hazard areas.

These characteristics allow the ADS System to be a virtual “drop-in” replacement for existing Halon 1301 gas fire suppression systems. Most installations will require only new nozzles and agent storage cylinders and can use most of the existing pipework—providing substantial savings when retrofitting existing systems. 

Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Technical Specifications Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Offers higher cylinder fill capacities for more efficient agent storage.

Increased agent flow rates and distances provide better coverage for larger hazard areas.

Smaller piping diameter results in installation cost savings.

Discharges the suppression agent the hazard in seconds.

Listing & Approvals

UL Listed

EPA Listed Agent

FM Approved

USCG Approved

ECS™ 360 psi Clean Agent Fire Suppression Systems

Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

ECS Clean Agent Fire Suppression Systems are the preferred fire suppression solution for facilities that cannot afford the downtime associated with a fire or typical water-based fire suppression systems. FM-200™ and 3M™ Novec™ 1230 Fire Protection Fluid Clean Agent systems extinguish a fire quickly by breaking down the molecular structure of the fire. The suppression agents do not harm the equipment or personnel in the protected room or cause a mess to clean up afterward.

Kidde Fire Systems ECS Clean Agents offer rapid-fire extinguishment, suppressing fires within seconds of the agent being discharged the protected area.  The agents are ventilated out of the space and do not leave behind a residue to be cleaned up, allowing your facility to get back to work immediately. 

ECS Clean Agents are non-toxic when used in compliance with NFPA Standard 2001. They do not impair breathing or obscure vision in an emergency situation, providing an added measure of safety for personnel.

Technical Specifications Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Engineered system providing a fast acting discharge in seconds

Offers fully-developed, flexible design limits to fit any application environment

Easy to design using our engineered series software

Listing & Approvals

UL Listed

ULC Listed

FM Approved

USCG Approved

MEA Listed

ECS-500™ psi Clean Agent Suppression System with 3M™ Novec™ 1230 Fire Protection Fluid

The ECS-500 psi Clean Agent Suppression System is the newest entry in our engineered clean agent suppression product line. The higher pressure (500 psi/34.5 bar) of the ECS-500 with 3M Novec 1230 Fire Protection Fluid provides superior system performance as compared to 360 psi/25 bar systems. Now you have the flexibility of a mid-tier solution between our standard ECS™ and Advanced Delivery System (ADS™) to meet application size and design requirements at the ECS 360 psi price. 

Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Benefits:

New 1,100 lb. cylinder reduces cylinder quantities and installation time required while providing enough agent to cover up to a 27,000 cubic feet area with a single cylinder

Increased system pressure allows for longer pipe runs and use of smaller pipe diameters

Provides flexibility to remotely locate cylinder storage area more than twice the distance the hazard area when compared to 360 psi/25 bar systems

Can be used with existing 4.0 HASP Key flow calculation software

Technical Specifications Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Easy to design using our engineered series software including pressure vent calculation

High performance system

Listing & Approvals

cULus Listed

FM Approved

USCG Approved

Other marine- and land-based approvals in process

Please refer to unburnt equipment provided by Dong Nam... HERE

You can refer to the manufacturer for more information....HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about Clean Agent Fire Suppression Systems FM-200™ HFC-227ea

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
Online support
0.13142 sec| 4334.32 kb