CCD-112, Central Fire Alarm Cabinet 12 zones (zone) Detnov

Manufacture: detnov
Product code: CCD-112

Structure: ABS shell, capable of being embedded
✔️ Multi-language keyboard. CPR certified EN54-2, EN54-4 and EN54-13 , Dimensions: 443 x 268 x 109 mm. , Requires 2 batteries BTD-1207 not included , Price list is vegetarian 2020

Zalo

Consulting hotline: 0944934114
Product information

Conventional fire detection cabinets with 12 zones. It distinguishes between detector alarm and push button alarm. Up to 32 detectors per zone. Possibility to connect to PC via USB for complex programming. Integrate with analog systems directly with the loop. It has two configurable supervisory siren outputs (maximum consumption 500 mA each), alarm and fault output by no-voltage relay, auxiliary 24V output (consumption 500 mA max.), resettable 24V output (max 500 mA consumption) and 1 programmable exterior input. Supports up to 3 expansion cards (TRD-100: 4 voltage-free relay outputs, TSD100: 4 supervised siren outputs, TMD-100: Modbus output for integration, TCD: Protocol Contact ID for connection to CRA, TPLD-100: integrated with analog loop). Maintenance and remote control via TED-151-CL card (Detnov Cloud).

° Alarm status relay output

° Fault status relay output 2 supervised audio outputs (500 mA each)

° Audio PCB delay setting

° Auxiliary 24V output (500 mA (1)) Resettable 24V output (500 mA (1))

° Configurable external input

°Test mode with automatic alarm

° Multi-language keyboard

°ABS cabin with built-in option

° Monitoring siren expansion option card

° Tension free relay expansion option card

°Communication option card

° CPR certification EN 54-2, EN 54-4 and EN 54-13

Specifications

Voltage 90-264VAC 50/60 Hz
Backup battery (battery) 2 x 7.5 Ah

Maximum current in zone alarm:

Maximum quiescent current for detector:

Maximum number of devices per zone:

Maximum resistance zone:

82 mA

3,5 mA

32 detectors / 10 push buttons

44 Ω

Maximum load:

Onboard selectable delay:

500 mA per output

0 - 10 minutes

Relay output no voltage 10A to 30VCC
Auxiliary 24V output 500 mA (1)

Maximum load:

Reset time:

500 mA (1)

5 minute

Temperature  -5ºC to 50ºC
Humidity 95%
Protections class IP30
Size 439 mm x 268 mm x 112 mm
Weight 1,9 kg
Certifications EN 54-2, EN 54-4 và EN 54-13 số
Certifications No 0370-CPR-3149  và PR-1811-064

Size

CCD-112,Tủ Báo Cháy Trung Tâm 12 vùng (zone) Detnov

Please see similar products….HERE  

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comment, evaluate about CCD-112, Central Fire Alarm Cabinet 12 zones (zone) Detnov

Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Comment
Click here to rate
Sender information
Product portfolio
0.14761 sec| 4341.461 kb