Nohmi FRRU004-CIZM4 Area Monitoring Module

Product code : FRRU004-CIZM4

The common zone monitoring module (FRRU004-CIZM4)is used to monitor the status of common initiating devices connected on , Initiating device circuit (IDC). The FRRU004-CIZM4 detects an alarm condition and reports it to the Fire Alarm Control Panel (FACP). The FRRU004-CIZM4 Modules also supervise the starting device wiring (wires A+, A-, B+ and B-) and wiring for the power connected to terminals 24+ and 24- for output open circuit current ,

Consulting hotline: 0944934114
Product information

IDC wiring pattern is applicable to NFPA Class B (Type B) & Class A (Type D). When the FRRU004-CIZM4 Module detects an alarm, the module is latched until the system resets. When the FRRU004-CIZM4 module is used with Wiring Condition Class A (Type D) and an open circuit is detected on the wire of the IDC and the power is connected to terminals 24+ and 24-, the module is is also latched until the system resets.

Basic Features Nohmi FRRU004-CIZM4 Area Monitoring Module

• A simple LED for status indication

• NFPA Class A (Style 6 & 7) and Class B (Type 4) for SLC

• NFPA Class A (Type D) and Class B (Type B) for IDC

• Set up electronic address

• Size reduction unit

• Easy to install

Specifications Nohmi FRRU004-CIZM4 Area Monitoring Module

No Item Parameter
1 SLC input rated voltage range (S+,S-) 22.0 to 24.0V
2 Maximum SLC 24VDC Standby Current (S+,S-) 250µA
3 24 VDC maximum SLC alarm current (S+,S-) 1mA
4 Voltage of the external power supply line (24+,24-) 24V
5 IDC output voltage range (A+,A-,B+,B-) 15.7 to 22.6V
6 IDC Module Maximum Standby Current 24VDC (24+,24-) 8.5mA of type B, 4.9mA of type D
7 Maximum detector standby current IDC 24VDC (24+,24-) 2.4mA
8 Alarm current IDC 24VDC max. Module and detector (24+,24-) 50.0mA
9 IDC wiring style is applied Class A (style D), class B (style B)
10 Maximum wire resistance of IDC 100Ω
11 IDC max wire power 1µF
12 End-of-line power for IDC in NFPA Type B wiring 5.1kΩ, 1/2W
13 Maximum warning voltage 0V
14 Minimum reset time 1.1 s
15 Working temperature 0°C to 49°C (32°F to 120°F)
16 Himidy 0 đến 93% (non-condensing)
17 Size 106mm (4.17 inches) (Cao) × 106mm (4.17 inches) (Rộng) × 29mm (1.14 inches) (Dài)
18 The box applies to the installation

64mm (2-1/2 inch) deep 2 cast iron box in North America Standard 4 inch square box 38mm (1-1/2 inch) deep box

Please see similar products….HERE

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comments, reviews about Nohmi FRRU004-CIZM4 Area Monitoring Module
Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Bình luận sản phẩm
Write a comment
Product portfolio
0.46804 sec| 4013.898 kb