120L FM200 Clean Agent Fire Suppression Gas System
In most buildings and ordinary places, water fire-fighting systems are generally used to extinguish fires, but in some special places such as data processing room, mobile communication base station, power distribution room, engine room, library and archives, precious cultural relics, exhibition hall warehouse Other places need to use gas fire extinguishing systems to extinguish fires to minimize fire losses and protect related equipment.
Product description of FM200
The FM200 system is suitable for fM-227ea fire extinguishing system installed in new construction, reconstruction and expansion projects and production and storage units. Widely used to protect:
1. Computer room, communication room, program-controlled switching room and other computer rooms;
2, generator room, transformer and distribution room, power plant, power station, precision instrument room,Laboratory, coating equipment room, oil depot, chemical flammable goods warehouse;
3. Archives, libraries, reference rooms, art galleries, museums, cultural relics, bank vaults and other places;
4, financial institutions, government agencies, TELEVISION broadcasting centers, hospitals, banks, buildings, factories and other expensive equipment can not be doused. It is suitable for extinguishing electrical fire, liquid fire or fusible solid fire, solid surface fire and gas fire which can cut off the gas source before extinguishing.
Product Specification of FM200
|
SYSTEM DATA |
|||
|
Model |
QMQ4.2/90N-JM | QMQ4.2/120N-JM | QMQ4.2/150N-JM |
|
Cylinder Capacity |
90L | 120L | 150L |
|
Cabinet Size(cm) |
90×50× 145 | 90×50× 160 | 90×50× 190 |
| Max. W. P | 5.3Mpa | ||
|
Storage Pressure |
4.2Mpa | ||
|
Working Temperature |
0~50°C (System room) | ||
|
Operating Voltage |
AC 220 V |
||
|
Back-Up Power |
DC 24 V |
||
|
Discharging Time |
≤10 S | ||
|
System Startup Method |
Automatic / Manual / Emergency operationOperation |
||
-Low concentration of HFC
-227ea required means less visual obscurity and minimal risk to personnel.
-Small quantity of agent discharged minimises over pressurisation of the protection area.
-Max Safety for personnel due to low toxicity.
-High effective with 10 second discharge time when used with automatic detection.
-Prevent re-ignition as long as concentration levels are maintained.
Applications
1)Computer Rooms
2)Data Processing Centers
3)Telecommunications And Communication Facilities
4)Process Control Centers
5)Expensive Medical Facilities
6)Valuable Industrial Equipment
7) Museums
8)Art Galleries
9)Libraries