Foam chambers are used in one of the most common applications to protect vertical (conical) fixed-roof liquid storage tanks, with or without an internal floating roof with low expansion foam systems.

Consulting hotline: 0944934114
Product information

Foam chambers are used in one of the most common applications to protect vertical (conical) roof fixed liquid storage tanks, with or without an internal floating roof with low expansion foam systems. The application of foam is on a risk basis including the total surface area of ​​the fuel. Commonly used foam system design guidelines are compliant with the NFPA-11 standard. The foam chamber is defined by NFPA-11 as a Class II outlet for the delivery of foam to the surface of a flammable liquid. Foam chambers are widely used with In-line foam inductors, pressure-balanced foam balancing systems, bladder tank balancing or foam tenders. The foam chamber is an air-suction foam discharge device, covering a wide flow range of 75 to 3600 liters per minute at an inlet pressure of 2.8 to 7 kg/m2. The foam chamber contains a vapor seal to prevent vapor ingress the foam chamber and foam solution tube. Each foam chamber is provided with an orifice plate, designed for the required flow and inlet pressure. Holes can replace the field in case of changing design parameters. Foam is created by introducing air a stream of foam solution. The inlet of the foam chamber is designed to create a venturi jet that draws air the foam solution stream. Air is drawn the foam solution through holes located in the porous cavity covered with stainless steel mesh to exclude birds and nesting insects. The aerated foam is directed at the deflector for gentle application of the expanded foam. The deflectors are available in different models. Removing the cover the top of the chamber allows the system to be tested and an expanded foam sample drawn, without removing the air cushion or disconnecting the foam chamber the tank. The odd broken glass disc (air seal) can be replaced very easily.

Specifications

Model FC
Size 50, 65, 80, 100 & 150 NB inlet
Working Pressure Minimum 2.8 Kg. / sq. cm.(40 PSI)
Maximum 7 Kg. / sq.cm. (100 PSI)
Flange Connection ANSI B 16.5 Class 150#
Approximate Weight FC 50- 28.0 Kg.
FC 65- 35.0 Kg.
FC 80- 52.0 Kg.
FC 100- 78.0 Kg.
FC 150-108.0 Kg.
Vapour Seal 0.7 to 1.75 Kg./sq.cm.(10 PSI TO 25 PSI)
Rupture Pressure Running water/Water foam solution pressure at the inlet of Foam Chamber.
Maximum Permissible Back Pressure On Vapour Seal 0.06 Kg./sq.cm. (0.9 PSI)
Finish Red epoxy painted
Ordering Iinformation

Model and size.

Inlet pressure.

Foam solution flow reqd.

Inlet, outlet flange specification.

Type of foam concentrate used.

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comments, reviews about Kvfire fire fighting foam chamber
Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Bình luận sản phẩm
Write a comment
Product portfolio
0.19926 sec| 3998.867 kb