FRRU004-DCM4, Dual Monitoring Module Nohmi

Product code : FRRU004-DCM4

Dual Contact Module (monitoring module )(FRRU004-DCM4) used to monitor multiple contact points with single addresses one device, the FRRU004-DCM4s can be configured to monitor normally open or normally closed contacts. In addition, the FRRU004-DCM4 can be configured as a single contact using Class A wiring methods. In the case of a supervisory contact, wiring is subject to Type wiring. A (Type D). I

Consulting hotline: 0944934114
Product information

n the case of two supervisory contacts, the wiring must follow Class B (Type B) wiring, the FRRU004-DCM4 is fully supervised if wired in accordance with the wiring diagram on the next page. The FRRU004-DCM4 uses a red LED to indicate status. Under normal conditions, the LED flashes. When the contact is activated, the LED will be on continuously. In the event of a problem, the LED will turn off. In the case of monitoring two contacts, if the conditions of the two contacts differ, the LED will fire with the higher priority condition. The highest priority of the contact condition is activated the contact condition, between the priority being open circuit and the lowest priority being the normal condition.

Feature

• A simple LED for status indication

• NFPA Class A (Style 6 & 7) and Class B (Type 4) for SLC

• NFPA Class A (Type D) and Class B (Type B) for IDC

• Set up electronic address

• Size reduction unit

• Easy to install

Specifications

Số Descriptions Specifiations
Case 1 joint supervision Case 2 joint supervision
1 SLC input source rated voltage range (S+,S-) 22.0 to 24.0V
2 SLC standby current 24 VDC max (S+,S-) 250µA
3 SLC alarm current 24 VDC max (S+.S-) 1mA
4 IDC . wire input NFPA class A (Type D) NFPA class B (type B)
5 Maximum wire resistance IDC 100Ω
6 Maximum wire capacitance IDC 1µF
7 Temperature 0°C to 49°C (32°F to 120°F)
8 Humidity 0 to 93% (no condensation)
9 Address on Module 1 address 2 address
10 Dimensions 106mm (4.17 inches) (Height) × 106mm (4.17 inches) (Width) × 29mm (1.14 inch) (Length)
11 Electrical box applicable for installation 64mm (2-1/2 inch) deep 2 cast iron box in North America Standard 4 inch square box 38mm (1-1/2 inch) deep box

Please see similar products….HERE 

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comments, reviews about FRRU004-DCM4, Dual Monitoring Module Nohmi
Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Bình luận sản phẩm
Write a comment
Product portfolio
0.39193 sec| 4001.797 kb