Electrically Actuated Deluge Valve 116-4FC

Product code : 116-4FC

Electrically controlled deluge valve, actuated by the pipeline pressure. The valve is closed in its normal, set position and opens when a 3-way solenoid valve is energized. It closes drip tight when the solenoid valve is de-energized. An emergency manual release valve is fitted as standard.

Consulting hotline: 0944934114
Product information

FEATURES & BENEFITS

Opens quickly when the solenoid valve is activated (specify energize-to-open or energize-to-close)

Manual override to open the valve regardless of solenoid valve position

Visual indicator for indication of valve position

Large supply drain port to drain inlet side piping

Solenoid operated main valve

No adjustments are necessary

Factory tested

UL Listed for deluge service in sizes 3” thru 10”

Can be installed vertically or horizontally

ANSI Flanged Class #150 or Class #300

Wide range of materials available

Options available including opening and/or closing speed controls, limit switch assembly and pressure gauge(s)

CERTIFICATION & COMPLIANCE

• ANSI FCI 70-2 Class VI seat leakage class

• Fire tested to EN ISO 19921

• UL listed under VLFT category

• ABS type approval

TYPICAL APPLICATIONS

Automatic or Manual Actuated Fire Suppression Systems

Petrochemical, Oil & Gas Installations

Tunnels

Power Generation, Transformer & Transmission Plants

Flammable Storage

Hangars & Airport Terminals

Onshore / Offshore

Mining

OPERATION

The basic control valve [1] used in this deluge system is a diaphragm actuated globe valve which closes with an elastomer-on-metal seal, hydraulically operated control valve engineered specifically for fire protection systems.

In the standby position, the deluge valve is held closed by the upstream water pressure, trapped in the valve’s control chamber. The water pressure enters the control chamber through the priming line ball valve [2], a Y-type strainer [3], a 3/2-way N.C. solenoid [6] and an auxiliary pilot valve [7].
Under fire conditions, a fire alarm control panel energizes the 3/2-way N.C. solenoid (or de-energizes the coil of a continuously energized ED 100% normally open solenoid for SIL 3-4 rated systems). The pressure in the auxiliary pilot valve vents to the atmosphere, causing it to shift position and allowing the water to drain the deluge valve’s control chamber. The deluge valve opens instantly and allows water to flow the pipeline and through the open sprinklers over the protected area.

Manual emergency actuation is enabled by opening the emergency manual activation valve [5]. The deluge valve opens instantly and allows water to flow the pipeline and through the open sprinklers over the protected area.

A visual indicator [4] provides indication of the valve’s position at a glance

TYPICAL MATERIALS

Xem thêm
Rút gọn
Frequently asked questions

You will receive a quote from us as soon as possible..

Have 0 comments, reviews about Electrically Actuated Deluge Valve 116-4FC
Welcome, honored guests. Please leave a comment, we will respond soon
Reply.
Sender information
Bình luận sản phẩm
Write a comment
Product portfolio
0.10966 sec| 4003.875 kb